Preventing wrong-site vertebroplasty procedures: An iterative quality improvement project

BACKGROUND AND PURPOSE: Wrong-site vertebroplasty is a known complication of image-guided procedures. Although rare, these errors have considerable clinical and medicolegal implications and are considered "never" events. This iterative quality improvement study set out to create and implement several new safeguard measures to ensure the prevention of wrong-site vertebroplasty procedures. MATERIALS AND METHODS: Iterative processes were enacted within a procedural practice of a neuroradiology division of a major academic institution. These focused on ensuring compliance of the primary outcome measure (obtaining and saving a fluoroscopy image that is marking the site(s) of interest with an overlying forceps) and process measure (requests that a CT and/or MRI image was inserted into the consult note, visually documenting the site(s) of interest). Because of the scarcity of wrong-site procedures, these were considered too rare to be useful for statistical evaluation. Balancing measures were put into place to monitor for unintended consequences: procedural radiation dosage, sedation time, and fluoroscopy time. RESULTS: Following a baseline period, three iterative quality improvement cycles occurred between October 1, 2025, and February 6, 2026. By the final phase, there was near perfect compliance with both obtaining pre-procedural fluoroscopy image and inserting an image into the consult note. Compliance with the saved pre-procedural fluoroscopy image was achieved, in part, due to initiation of a "second time-out" in which a technologist would remind the physician to obtain and save a fluoroscopy image. The balancing measures showed no significant change, and thus no unintended consequence, over the course of this project. CONCLUSIONS: Several measures can be easily implemented to serve as safeguards against a wrong-site vertebroplasty, but may require several iterations to ensure full compliance.

Authors

Institutions

Publication Details

Journal
American Journal of Neuroradiology
Published
2026-05-21
DOI
https://doi.org/10.3174/ajnr.a9429
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preventing wrong-site vertebroplasty procedures: An iterative quality improvement project

Jared T. Verdoorn, Ian T. Mark, Catherine Kreatsoulas, Chelsea J. Dahl et al.
American Journal of Neuroradiology
Spinal Fractures and Fixation Techniques
article

Preventing wrong-site vertebroplasty procedures: An iterative quality improvement project

Jared T. Verdoorn, Ian T. Mark, Catherine Kreatsoulas, Chelsea J. Dahl, Benjamin A. Johnson‐Tesch, Greta B. Liebo, Dong K Kim, Carrie M. Carr, Darya P. Shlapak, Michael P Oien, John C. Benson, Pearse P. Morris, Michelle L. Kodet, Theodore A. Betting
article en

Abstract

BACKGROUND AND PURPOSE: Wrong-site vertebroplasty is a known complication of image-guided procedures. Although rare, these errors have considerable clinical and medicolegal implications and are considered "never" events. This iterative quality improvement study set out to create and implement several new safeguard measures to ensure the prevention of wrong-site vertebroplasty procedures. MATERIALS AND METHODS: Iterative processes were enacted within a procedural practice of a neuroradiology division of a major academic institution. These focused on ensuring compliance of the primary outcome measure (obtaining and saving a fluoroscopy image that is marking the site(s) of interest with an overlying forceps) and process measure (requests that a CT and/or MRI image was inserted into the consult note, visually documenting the site(s) of interest). Because of the scarcity of wrong-site procedures, these were considered too rare to be useful for statistical evaluation. Balancing measures were put into place to monitor for unintended consequences: procedural radiation dosage, sedation time, and fluoroscopy time. RESULTS: Following a baseline period, three iterative quality improvement cycles occurred between October 1, 2025, and February 6, 2026. By the final phase, there was near perfect compliance with both obtaining pre-procedural fluoroscopy image and inserting an image into the consult note. Compliance with the saved pre-procedural fluoroscopy image was achieved, in part, due to initiation of a "second time-out" in which a technologist would remind the physician to obtain and save a fluoroscopy image. The balancing measures showed no significant change, and thus no unintended consequence, over the course of this project. CONCLUSIONS: Several measures can be easily implemented to serve as safeguards against a wrong-site vertebroplasty, but may require several iterations to ensure full compliance.

American Journal of Neuroradiology
Harvard University (US), Hesco (United States) (US)
Openalex Percentile: Top 5%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.