Optimal Selection of Biodegradable Polymer Composites for Load-Bearing Bone Tissue Engineering: A Hybrid Fuzzy AHP-TOPSIS Framework with Sensitivity-Based Robustness Analysis

The development of biodegradable scaffolds for load-bearing bone tissue engineering (BTE) presents a fundamental multi-criteria optimization challenge, requiring a simultaneous balance among mechanical performance, biological integration, and degradation kinetics. These criteria are inherently conflicting: composite formulations with the highest compressive strength frequently exhibit suboptimal porosity, while those with superior osteoconductivity often lack sufficient load-bearing capacity. To address this challenge rigorously, this study establishes a hybrid Fuzzy Analytic Hierarchy Process–Technique for Order of Preference by Similarity to Ideal Solution (Fuzzy AHP-TOPSIS) framework to evaluate and rank five clinically relevant biodegradable polymer–ceramic composite candidates: PLA/Hydroxyapatite (PLA/HA), PCL/Hydroxyapatite (PCL/HA), PLGA/Bioactive Glass (PLGA/BG), PLA/Carbon Nanotubes (PLA/CNT), and PLA/Magnesium (PLA/Mg). Quantitative property data were systematically extracted from ten peer-reviewed experimental studies published between 2021 and 2025, and converted into Triangular Fuzzy Numbers (TFNs) to explicitly model inter-study variability arising from differences in fabrication methods, filler loading, and testing conditions. Fuzzy AHP analysis identified Compressive Strength (w = 25.2%) and Cell Viability (w = 21.5%) as the dominant decision criteria for load-bearing cortical bone repair. The Fuzzy TOPSIS ranking identified PLA/HA as the optimal composite candidate (Closeness Coefficient, CCᵢ = 0.677), demonstrating the superior multi-criteria balance required for cortical bone repair applications. Although PLA/CNT achieved the highest mechanical strength, it was outranked due to lower osteoconductivity and elevated cytotoxicity uncertainty at high nanotube concentrations (CCᵢ = 0.544). Sensitivity analysis across five distinct weighting scenarios confirmed the robustness of PLA/HA as the primary candidate. These findings provide a validated, replicable computational blueprint for evidence-based scaffold material selection, with direct implications for reducing the burden of costly trial-and-error experimentation in BTE research.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-05-21
DOI
https://doi.org/10.3390/jfb17050258
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Selection of Biodegradable Polymer Composites for Load-Bearing Bone Tissue Engineering: A Hybrid Fuzzy AHP-TOPSIS Framework with Sensitivity-Based Robustness Analysis

Berna Uzun, Dilber Uzun Ozsahin, Lafi Hamidat
Journal of Functional Biomaterials
Bone Tissue Engineering Materials
article

Optimal Selection of Biodegradable Polymer Composites for Load-Bearing Bone Tissue Engineering: A Hybrid Fuzzy AHP-TOPSIS Framework with Sensitivity-Based Robustness Analysis

Berna Uzun, Dilber Uzun Ozsahin, Lafi Hamidat
article en

Abstract

The development of biodegradable scaffolds for load-bearing bone tissue engineering (BTE) presents a fundamental multi-criteria optimization challenge, requiring a simultaneous balance among mechanical performance, biological integration, and degradation kinetics. These criteria are inherently conflicting: composite formulations with the highest compressive strength frequently exhibit suboptimal porosity, while those with superior osteoconductivity often lack sufficient load-bearing capacity. To address this challenge rigorously, this study establishes a hybrid Fuzzy Analytic Hierarchy Process–Technique for Order of Preference by Similarity to Ideal Solution (Fuzzy AHP-TOPSIS) framework to evaluate and rank five clinically relevant biodegradable polymer–ceramic composite candidates: PLA/Hydroxyapatite (PLA/HA), PCL/Hydroxyapatite (PCL/HA), PLGA/Bioactive Glass (PLGA/BG), PLA/Carbon Nanotubes (PLA/CNT), and PLA/Magnesium (PLA/Mg). Quantitative property data were systematically extracted from ten peer-reviewed experimental studies published between 2021 and 2025, and converted into Triangular Fuzzy Numbers (TFNs) to explicitly model inter-study variability arising from differences in fabrication methods, filler loading, and testing conditions. Fuzzy AHP analysis identified Compressive Strength (w = 25.2%) and Cell Viability (w = 21.5%) as the dominant decision criteria for load-bearing cortical bone repair. The Fuzzy TOPSIS ranking identified PLA/HA as the optimal composite candidate (Closeness Coefficient, CCᵢ = 0.677), demonstrating the superior multi-criteria balance required for cortical bone repair applications. Although PLA/CNT achieved the highest mechanical strength, it was outranked due to lower osteoconductivity and elevated cytotoxicity uncertainty at high nanotube concentrations (CCᵢ = 0.544). Sensitivity analysis across five distinct weighting scenarios confirmed the robustness of PLA/HA as the primary candidate. These findings provide a validated, replicable computational blueprint for evidence-based scaffold material selection, with direct implications for reducing the burden of costly trial-and-error experimentation in BTE research.

Journal of Functional BiomaterialsVol. 17(5)
University of Sharjah (AE), Mersin Üniversitesi (TR), Near East University (CY)
Openalex Percentile: Top 10%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.