Digital fabrication accuracy and fit analysis of additively and subtractively manufactured zirconia fixed dental prostheses.

Objectives To compare the fabrication accuracy and fit of three-unit fixed dental prostheses (FDPs) manufactured additively from a 3Y-TZP slurry with those manufactured subtractively from a translucent or a strength-gradient zirconia. Methods Forty-five three-unit posterior FDPs were fabricated either additively from a 3Y-TZP slurry (Cera-P, AM) or subtractively from a translucent (4Y-TZP, n!ce Zirconia HT, SM-HT) or a strength-gradient zirconia (3/5 Y-TZP, IPS e.max ZirCAD Prime, SM-SG) (n = 15). Surface deviations (external, intaglio, marginal, and overall) and average gaps (fit) of the FDPs were digitally analyzed. Data were analyzed with one-way analysis of variance and Tukey (surface deviations) or Tamhane tests (average gaps). Precision was defined as the average of measured values from the mean value, and analyzed similar to each outcome (α = 0.05). Results AM FDPs exhibited the highest deviations across all surfaces but the lowest gaps (P < .001) and no significant differences were detected between SM-HT and SM-SG (P ≥ 0.360). There was no difference in the precision of measured deviations (P ≥ 0.057). When the precision of average gap values was considered, AM FDPs had higher values than SM-SG FDPs (P = 0.024). Conclusions AM FDPs demonstrated the lowest fabrication trueness, while SM-SG and SM-HT FDPs had similar fabrication accuracy. Although AM FDPs exhibited improved fit, their fit precision was inferior to SM-SG FDPs, whereas SM-SG and SM-HT FDPs had similar fit accuracy. The fit of all FDPs remained within clinically acceptable limits.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-09-01
DOI
https://doi.org/10.48620/97883
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Digital fabrication accuracy and fit analysis of additively and subtractively manufactured zirconia fixed dental prostheses.

Çiğdem Kahveci, Gülce Çakmak, Eleni Trikoili, Zeynep Yertutan et al.
Open Access CRIS of the University of Bern
Dental materials and restorations
article

Digital fabrication accuracy and fit analysis of additively and subtractively manufactured zirconia fixed dental prostheses.

Çiğdem Kahveci, Gülce Çakmak, Eleni Trikoili, Zeynep Yertutan, Mustafa Borga Dönmez, Begüm Ünlü Kurşun, Burak Yilmaz
article en

Abstract

Objectives To compare the fabrication accuracy and fit of three-unit fixed dental prostheses (FDPs) manufactured additively from a 3Y-TZP slurry with those manufactured subtractively from a translucent or a strength-gradient zirconia. Methods Forty-five three-unit posterior FDPs were fabricated either additively from a 3Y-TZP slurry (Cera-P, AM) or subtractively from a translucent (4Y-TZP, n!ce Zirconia HT, SM-HT) or a strength-gradient zirconia (3/5 Y-TZP, IPS e.max ZirCAD Prime, SM-SG) (n = 15). Surface deviations (external, intaglio, marginal, and overall) and average gaps (fit) of the FDPs were digitally analyzed. Data were analyzed with one-way analysis of variance and Tukey (surface deviations) or Tamhane tests (average gaps). Precision was defined as the average of measured values from the mean value, and analyzed similar to each outcome (α = 0.05). Results AM FDPs exhibited the highest deviations across all surfaces but the lowest gaps (P < .001) and no significant differences were detected between SM-HT and SM-SG (P ≥ 0.360). There was no difference in the precision of measured deviations (P ≥ 0.057). When the precision of average gap values was considered, AM FDPs had higher values than SM-SG FDPs (P = 0.024). Conclusions AM FDPs demonstrated the lowest fabrication trueness, while SM-SG and SM-HT FDPs had similar fabrication accuracy. Although AM FDPs exhibited improved fit, their fit precision was inferior to SM-SG FDPs, whereas SM-SG and SM-HT FDPs had similar fit accuracy. The fit of all FDPs remained within clinically acceptable limits.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Openalex Percentile: Top 51%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Digital fabrication accuracy and fit analysis of additively and subtractively manufactured zirconia fixed dental prostheses. — Çiğdem Kahveci, Gülce Çakmak, et al. · Open Access CRIS of the University of Bern (2026) | TGRS Research Map | TGRS