Optimization and evaluation of venturi tube reactors for non-thermal milk pasteurization using CFD method

With growing demand for preserving food’s nutritional and sensory qualities, non-thermal pasteurization methods like hydrodynamic cavitation in Venturi tubes offer an effective alternative to heat-based techniques. This study optimizes a Venturi reactor for milk pasteurization using computational fluid dynamics (CFD) with the k-ε turbulence model and response surface method (RSM). By adjusting throat diameter (4.91 mm), length (13.15 mm), and convergence/divergence angles (19.2°/8.31°), the design maximized turbulent kinetic energy (TKE) (0.2438 m²/s² peak, 0.0305 m²/s² average) and minimized energy loss (viscous dissipation 2.69 W, pressure drop 3483 Pa). Experiments confirmed a 2.91 log-reduction in E. coli , with negligible impact on milk’s fat, protein, and lactose, ensuring safety and quality.

Authors

Publication Details

Journal
PLoS ONE
Published
2026-05-19
DOI
https://doi.org/10.1371/journal.pone.0349354
Primary Topic
Ultrasound and Cavitation Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization and evaluation of venturi tube reactors for non-thermal milk pasteurization using CFD method

Sajad Rostami, Kimia Taki, Firozeh Nazari, Bahram Hosseinzadeh Samani et al.
PLoS ONE
Ultrasound and Cavitation Phenomena
article

Optimization and evaluation of venturi tube reactors for non-thermal milk pasteurization using CFD method

Sajad Rostami, Kimia Taki, Firozeh Nazari, Bahram Hosseinzadeh Samani, Zahra Izadi
article en

Abstract

With growing demand for preserving food’s nutritional and sensory qualities, non-thermal pasteurization methods like hydrodynamic cavitation in Venturi tubes offer an effective alternative to heat-based techniques. This study optimizes a Venturi reactor for milk pasteurization using computational fluid dynamics (CFD) with the k-ε turbulence model and response surface method (RSM). By adjusting throat diameter (4.91 mm), length (13.15 mm), and convergence/divergence angles (19.2°/8.31°), the design maximized turbulent kinetic energy (TKE) (0.2438 m²/s² peak, 0.0305 m²/s² average) and minimized energy loss (viscous dissipation 2.69 W, pressure drop 3483 Pa). Experiments confirmed a 2.91 log-reduction in E. coli , with negligible impact on milk’s fat, protein, and lactose, ensuring safety and quality.

PLoS ONEVol. 21(5)
Zero hunger
Openalex Percentile: Top 10%
Ultrasound and Cavitation Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.