Deep learning-based motion correction: cardiac motion artifact and image quality improvements on chest CT

Abstract Purpose Since the clinical application of computed tomography (CT), cardiac and respiratory motion artifacts have caused decreased image quality and reduced detection or quantitative or qualitative evaluation of lung parenchymal or vascular abnormalities on chest CT with lung window settings in patients with pulmonary diseases. Recently, a deep learning (DL)-based motion correction algorithm (CLEAR Motion) has been developed and clinically used for chest CT. We hypothesized that CLEAR Motion can significantly reduce motion artifacts on chest CT examinations relative to conventional chest CT images reconstructed without CLEAR Motion. The purpose of this study was to determine the utility of CLEAR Motion for image quality improvement in chest CT with lung window settings in patients with various pulmonary diseases. Materials and methods Fifty-six consecutive patients with various thoracic diseases underwent non-electrocardiogram-gated chest helical CT examination using a 320-detector row CT and underwent reconstruction using the conventional reconstruction method and CLEAR Motion. To compare the quantitative image quality, the cardio-pulmonary edge distance (CPED) and slope (CPES) were measured on each CT scan in the axial plane. Comparing cardiac motion reduction capability, overall image quality, cardiac motion artifact, and region conspicuity were visually assessed in the lung window setting on the axial, coronal, and sagittal planes. The paired t-test and Wilcoxon signed-rank test were then performed. Results The CPEDs and CPESs of the entire lung and left lung on CT with CLEAR Motion were significantly superior to those of CT without CLEAR Motion ( p < 0.001). The overall image quality, cardiac motion artifact, and region conspicuity on CT with CLEAR Motion were significantly higher than those without CLEAR Motion on each plane ( p < 0.001). Conclusion The DL-based motion correction algorithm named as ‘CLEAR Motion’ has a potential to improve image quality on chest CT with lung window setting in patients with pulmonary diseases.

Authors

Publication Details

Journal
Japanese Journal of Radiology
Published
2026-05-20
DOI
https://doi.org/10.1007/s11604-026-01986-8
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep learning-based motion correction: cardiac motion artifact and image quality improvements on chest CT

Naruomi Akino, Hirona Kimata, Yoshiharu Ohno, Yuya Ito et al.
Japanese Journal of Radiology
Cardiac Imaging and Diagnostics
article

Deep learning-based motion correction: cardiac motion artifact and image quality improvements on chest CT

Naruomi Akino, Hirona Kimata, Yoshiharu Ohno, Yuya Ito, Masahiko Nomura, Masahiro Endo, Kenji Fujii, Daisuke Takenaka, Yoshiyuki Ozawa, Takahiro Ueda, Takeshi Yoshikawa
article en

Abstract

Abstract Purpose Since the clinical application of computed tomography (CT), cardiac and respiratory motion artifacts have caused decreased image quality and reduced detection or quantitative or qualitative evaluation of lung parenchymal or vascular abnormalities on chest CT with lung window settings in patients with pulmonary diseases. Recently, a deep learning (DL)-based motion correction algorithm (CLEAR Motion) has been developed and clinically used for chest CT. We hypothesized that CLEAR Motion can significantly reduce motion artifacts on chest CT examinations relative to conventional chest CT images reconstructed without CLEAR Motion. The purpose of this study was to determine the utility of CLEAR Motion for image quality improvement in chest CT with lung window settings in patients with various pulmonary diseases. Materials and methods Fifty-six consecutive patients with various thoracic diseases underwent non-electrocardiogram-gated chest helical CT examination using a 320-detector row CT and underwent reconstruction using the conventional reconstruction method and CLEAR Motion. To compare the quantitative image quality, the cardio-pulmonary edge distance (CPED) and slope (CPES) were measured on each CT scan in the axial plane. Comparing cardiac motion reduction capability, overall image quality, cardiac motion artifact, and region conspicuity were visually assessed in the lung window setting on the axial, coronal, and sagittal planes. The paired t-test and Wilcoxon signed-rank test were then performed. Results The CPEDs and CPESs of the entire lung and left lung on CT with CLEAR Motion were significantly superior to those of CT without CLEAR Motion ( p < 0.001). The overall image quality, cardiac motion artifact, and region conspicuity on CT with CLEAR Motion were significantly higher than those without CLEAR Motion on each plane ( p < 0.001). Conclusion The DL-based motion correction algorithm named as ‘CLEAR Motion’ has a potential to improve image quality on chest CT with lung window setting in patients with pulmonary diseases.

Japanese Journal of Radiology
Openalex Percentile: Top 4%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.