Fully automated artificial intelligence–based echocardiographic analysis substantially reduces workflow time while preserving measurement accuracy: a pilot study

Abstract Background Transthoracic echocardiography (TTE) requires time-intensive integration of quantitative measurements and qualitative visual assessment. Fully automated artificial intelligence (AI)-based analysis may reduce total analysis time while preserving accuracy, but systematic real-world validation remains limited. Methods This prospective, single-center pilot study enrolled 40 TTE examinations. Identical deidentified DICOM datasets were independently provided to a trained cardiac sonographer and a fully automated AI system comprising quantitative and qualitative visual interpretation modules. All outputs were compared with a cardiologist-adjudicated reference standard. Primary endpoints were total analysis time and noninferiority of AI-derived left ventricular ejection fraction (LVEF) versus the reference standard, with a prespecified margin of 3 percentage points (one-sided α = 0.025). Results Median analysis time was 94 s (interquartile range [IQR], 82–106 s) for the AI workflow versus 490 s (IQR, 438–626 s) for the human workflow (P < 0.001). AI-derived LVEF met the noninferiority criterion (mean difference, 0.00 percentage points; upper one-sided 95% confidence bound, 1.41 percentage points; P < 0.001), with an intraclass correlation coefficient (ICC) of 0.902 (95% confidence interval, 0.822–0.947). ICCs for secondary quantitative indices ranged from 0.625 to 0.989. For aortic regurgitation severity grading, AI’s overall accuracy was 75.0% (quadratic weighted κ = 0.762), compared with 82.5% for human interpretation (κ = 0.812, McNemar P = 0.579). Conclusions Fully automated AI-assisted TTE analysis substantially reduced total analysis time while maintaining noninferior LVEF accuracy and acceptable performance across secondary quantitative and qualitative indices. These findings support the use of AI as a practical workflow accelerator in routine echocardiography.

Authors

Publication Details

Journal
Journal of Cardiovascular Imaging
Published
2026-05-20
DOI
https://doi.org/10.1186/s44348-026-00073-w
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fully automated artificial intelligence–based echocardiographic analysis substantially reduces workflow time while preserving measurement accuracy: a pilot study

이지연, Yeonyee E. Yoon, Jiesuck Park, Ganghan Lee et al.
Journal of Cardiovascular Imaging
Cardiovascular Function and Risk Factors
article

Fully automated artificial intelligence–based echocardiographic analysis substantially reduces workflow time while preserving measurement accuracy: a pilot study

이지연, Yeonyee E. Yoon, Jiesuck Park, Ganghan Lee, Hong-Mi Choi, In-Chang Hwang, Jonghee Sun, Minjung Bak, Goo-Yeong Cho
article en

Abstract

Abstract Background Transthoracic echocardiography (TTE) requires time-intensive integration of quantitative measurements and qualitative visual assessment. Fully automated artificial intelligence (AI)-based analysis may reduce total analysis time while preserving accuracy, but systematic real-world validation remains limited. Methods This prospective, single-center pilot study enrolled 40 TTE examinations. Identical deidentified DICOM datasets were independently provided to a trained cardiac sonographer and a fully automated AI system comprising quantitative and qualitative visual interpretation modules. All outputs were compared with a cardiologist-adjudicated reference standard. Primary endpoints were total analysis time and noninferiority of AI-derived left ventricular ejection fraction (LVEF) versus the reference standard, with a prespecified margin of 3 percentage points (one-sided α = 0.025). Results Median analysis time was 94 s (interquartile range [IQR], 82–106 s) for the AI workflow versus 490 s (IQR, 438–626 s) for the human workflow (P < 0.001). AI-derived LVEF met the noninferiority criterion (mean difference, 0.00 percentage points; upper one-sided 95% confidence bound, 1.41 percentage points; P < 0.001), with an intraclass correlation coefficient (ICC) of 0.902 (95% confidence interval, 0.822–0.947). ICCs for secondary quantitative indices ranged from 0.625 to 0.989. For aortic regurgitation severity grading, AI’s overall accuracy was 75.0% (quadratic weighted κ = 0.762), compared with 82.5% for human interpretation (κ = 0.812, McNemar P = 0.579). Conclusions Fully automated AI-assisted TTE analysis substantially reduced total analysis time while maintaining noninferior LVEF accuracy and acceptable performance across secondary quantitative and qualitative indices. These findings support the use of AI as a practical workflow accelerator in routine echocardiography.

Journal of Cardiovascular ImagingVol. 34(1)
Openalex Percentile: Top 5%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.