High-frequency thermal noise in Michelson interferometers

Thermal noise in optics constrains the precision of optical experiments, including Michelson interferometers, optical clocks, and optomechanical sensors. While high-power optical experiments such as gravitational-wave detectors are currently limited mainly by quantum noise, new experiments incorporating recent insights from quantum metrology are being developed that evade the quantum shot noise background. In particular, Michelson interferometers that use photon-counting readout will look for weak, high-frequency signals. Since shot noise is no longer the dominant noise source with these readout schemes, it is important to accurately model thermal noise to characterize signals and design more sensitive experiments. However, previous modeling uses approximations that are no longer valid in these frequency regimes. In the MHz band, the quasistatic approximation does not apply. We therefore develop more general models of substrate and coating mechanical (Brownian) noise, substrate and coating thermoelastic noise, and coating thermorefractive noise. We validate the models with comparisons to previous low-frequency modeling and high-frequency spectra from an experiment that has already taken data, the Holometer. We then apply the new models to GQuEST, an experiment under construction.

Authors

Publication Details

Journal
Physical review. D/Physical review. D.
Published
2026-11-19
DOI
https://doi.org/10.1103/7kw1-sh6m
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

High-frequency thermal noise in Michelson interferometers

S. M. Vermeulen, Daniel Graß, Lee McCuller, I. A. O. MacMillan
Physical review. D/Physical review. D.
Mechanical and Optical Resonators
article

High-frequency thermal noise in Michelson interferometers

S. M. Vermeulen, Daniel Graß, Lee McCuller, I. A. O. MacMillan
article en

Abstract

Thermal noise in optics constrains the precision of optical experiments, including Michelson interferometers, optical clocks, and optomechanical sensors. While high-power optical experiments such as gravitational-wave detectors are currently limited mainly by quantum noise, new experiments incorporating recent insights from quantum metrology are being developed that evade the quantum shot noise background. In particular, Michelson interferometers that use photon-counting readout will look for weak, high-frequency signals. Since shot noise is no longer the dominant noise source with these readout schemes, it is important to accurately model thermal noise to characterize signals and design more sensitive experiments. However, previous modeling uses approximations that are no longer valid in these frequency regimes. In the MHz band, the quasistatic approximation does not apply. We therefore develop more general models of substrate and coating mechanical (Brownian) noise, substrate and coating thermoelastic noise, and coating thermorefractive noise. We validate the models with comparisons to previous low-frequency modeling and high-frequency spectra from an experiment that has already taken data, the Holometer. We then apply the new models to GQuEST, an experiment under construction.

Physical review. D/Physical review. D.
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon