Restroom Hygiene and Resource Optimizer: Design, Implementation, and Experimental Validation

This paper presents the design, hardware implementation, and experimental evaluation of an integrated smart restroom hygiene and resource management system. The developed prototype employs an ESP32 microcontroller as its central processing unit and incorporates an MQ-135 gas sensor for air quality monitoring, a DHT11 sensor for temperature and humidity measurement, an infrared sensor for occupancy detection, an ultrasonic sensor for contactless automated flushing, and float sensors for water and sewage level supervision. Unlike existing systems that address individual restroom challenges in isolation, the proposed system unifies all subsystems into a single embedded platform capable of real-time local decision-making without dependence on continuous cloud connectivity. Experimental results demonstrate reliable sensor performance, occupancy-based energy reduction of approximately 50–60%, consistent automated flushing response, and timely wireless maintenance alerts via the Blynk platform. The system offers a low-cost, scalable, and autonomous solution suitable for deployment in high-footfall public sanitation facilities.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-05-19
DOI
https://doi.org/10.5281/zenodo.20282404
Primary Topic
Water Quality Monitoring Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Restroom Hygiene and Resource Optimizer: Design, Implementation, and Experimental Validation

Shrushti Channe, Prajwal Yesambare, Nishant Ganvir, Sejal Mendhule et al.
Zenodo (CERN European Organization for Nuclear Research)
Water Quality Monitoring Technologies
article

Restroom Hygiene and Resource Optimizer: Design, Implementation, and Experimental Validation

Shrushti Channe, Prajwal Yesambare, Nishant Ganvir, Sejal Mendhule, Arya Darne, Dr. Pravin Pokle
article en

Abstract

This paper presents the design, hardware implementation, and experimental evaluation of an integrated smart restroom hygiene and resource management system. The developed prototype employs an ESP32 microcontroller as its central processing unit and incorporates an MQ-135 gas sensor for air quality monitoring, a DHT11 sensor for temperature and humidity measurement, an infrared sensor for occupancy detection, an ultrasonic sensor for contactless automated flushing, and float sensors for water and sewage level supervision. Unlike existing systems that address individual restroom challenges in isolation, the proposed system unifies all subsystems into a single embedded platform capable of real-time local decision-making without dependence on continuous cloud connectivity. Experimental results demonstrate reliable sensor performance, occupancy-based energy reduction of approximately 50–60%, consistent automated flushing response, and timely wireless maintenance alerts via the Blynk platform. The system offers a low-cost, scalable, and autonomous solution suitable for deployment in high-footfall public sanitation facilities.

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 9%
Water Quality Monitoring Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.