Dynamic Intraoperative Interpretation of TIM Heatmaps: Fluoroscopic Correlation of Skip and Central Heat TIM Patterns in Cochlear Malformation

Objective: To describe intraoperative fluoroscopic and transimpedance matrix (TIM) findings during cochlear implantation in a patient with bilateral cochlear malformations, highlighting the dynamic relationship between electrode position and evolving TIM heatmap patterns. Study design: Case report. Methods: Retrospective review of patient medical and radiographic records, intraoperative fluoroscopy, and TIM data. Results: Initial insertion produced a previously characterized TIM skip heat pattern seen in patients with incomplete partition type II and deficient interscalar septal width. This prompted partial electrode withdrawal under fluoroscopy, which subsequently resulted in a TIM central heat pattern, representing a symmetric voltage concentration around the mid-array region. Advancing the array slightly resulted in a skip heat pattern with a more defined current delineation and a more favorable x-ray profile. Interestingly, SmartNav analysis interpreted the TIM data as a tip fold over, despite good positioning. Conclusion: This case visually demonstrates which small positional changes of electrodes within malformed cochleae can transform TIM morphology, helping to elucidate why certain patterns occur, and the next steps to study clinical relevance.

Institutions

Publication Details

Journal
Otology & Neurotology
Published
2026-05-19
DOI
https://doi.org/10.1097/mao.0000000000004944
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Intraoperative Interpretation of TIM Heatmaps: Fluoroscopic Correlation of Skip and Central Heat TIM Patterns in Cochlear Malformation

Otology & Neurotology
Hearing Loss and Rehabilitation
article

Dynamic Intraoperative Interpretation of TIM Heatmaps: Fluoroscopic Correlation of Skip and Central Heat TIM Patterns in Cochlear Malformation

article en

Abstract

Objective: To describe intraoperative fluoroscopic and transimpedance matrix (TIM) findings during cochlear implantation in a patient with bilateral cochlear malformations, highlighting the dynamic relationship between electrode position and evolving TIM heatmap patterns. Study design: Case report. Methods: Retrospective review of patient medical and radiographic records, intraoperative fluoroscopy, and TIM data. Results: Initial insertion produced a previously characterized TIM skip heat pattern seen in patients with incomplete partition type II and deficient interscalar septal width. This prompted partial electrode withdrawal under fluoroscopy, which subsequently resulted in a TIM central heat pattern, representing a symmetric voltage concentration around the mid-array region. Advancing the array slightly resulted in a skip heat pattern with a more defined current delineation and a more favorable x-ray profile. Interestingly, SmartNav analysis interpreted the TIM data as a tip fold over, despite good positioning. Conclusion: This case visually demonstrates which small positional changes of electrodes within malformed cochleae can transform TIM morphology, helping to elucidate why certain patterns occur, and the next steps to study clinical relevance.

Otology & Neurotology
Yale New Haven Hospital (US), Yale University (US), NYU Langone Health (US)
Openalex Percentile: Top 4%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.