The isolated working guinea pig heart: A functional and electrophysiological characterisation

Abstract Small animal isolated perfused hearts have been used for over 150 years for the study of cardiac physiology and pharmacology. The guinea pig heart represents the smallest mammalian heart that replicates key features of the human heart – for example, with respect to cardiac action potential duration, ion channel expression, excitation–contraction coupling and intracellular Ca 2+ handling. In this study we describe the apparatus, instrumentation and characterisation of the isolated working guinea pig heart and utilise state‐of‐the‐art pressure–volume catheters and so forth to characterise systolic and diastolic function in this auxotonically contracting preparation. We describe novel correction formulae to allow rate‐dependent variables, such as the QT interval of the ECG and left‐ventricular pressure, to be reliably corrected for changes in heart rate.

Institutions

Publication Details

Journal
Experimental Physiology
Published
2026-05-19
DOI
https://doi.org/10.1113/ep093591
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The isolated working guinea pig heart: A functional and electrophysiological characterisation

Experimental Physiology
Cardiac electrophysiology and arrhythmias
article

The isolated working guinea pig heart: A functional and electrophysiological characterisation

article en

Abstract

Abstract Small animal isolated perfused hearts have been used for over 150 years for the study of cardiac physiology and pharmacology. The guinea pig heart represents the smallest mammalian heart that replicates key features of the human heart – for example, with respect to cardiac action potential duration, ion channel expression, excitation–contraction coupling and intracellular Ca 2+ handling. In this study we describe the apparatus, instrumentation and characterisation of the isolated working guinea pig heart and utilise state‐of‐the‐art pressure–volume catheters and so forth to characterise systolic and diastolic function in this auxotonically contracting preparation. We describe novel correction formulae to allow rate‐dependent variables, such as the QT interval of the ECG and left‐ventricular pressure, to be reliably corrected for changes in heart rate.

Experimental Physiology
St Thomas' Hospital (GB)
British Heart Foundation
Openalex Percentile: Top 5%
Cardiac electrophysiology and arrhythmias
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.