Breast Ultrasound AI Under Dataset Shift: A Patient-Leakage-Aware Benchmark

Background: Artificial intelligence (AI) has shown promise in breast ultrasound image analysis, but most evidence still comes from single-dataset studies. Clinical translation requires evaluation under heterogeneous acquisition and curation conditions. This study presents a patient-leakage-aware, reproducible benchmark for breast ultrasound AI under dataset shift, with emphasis on external generalization, calibration, and confidence-related behavior. Methods: A reproducible benchmark framework was developed using patient-level splitting, internal testing, pairwise cross-dataset evaluation, whole-image and region-of-interest (ROI) input strategies, calibration analysis, targeted ROI-margin sensitivity analysis, representative explainable AI visualization, and an auxiliary lesion-versus-normal confidence-based analysis. Four public breast ultrasound datasets (BUSI, BUS-UCLM, BUS-BRA, and BrEaST) were harmonized for a primary benign-versus-malignant lesion classification task. Normal images were excluded from the primary endpoint and used only in auxiliary analyses when sufficient numbers were available. Results: Cross-dataset testing was weaker on average than internal testing, with mean raw AUROC decreasing from 0.801 to 0.719 and mean balanced accuracy from 0.723 to 0.635. ROI input improved external performance, especially for the vision transformer, increasing mean external AUROC from 0.666 to 0.805 and mean external balanced accuracy from 0.594 to 0.713 relative to whole-image input. Temperature scaling improved calibration-related metrics, reducing mean external expected calibration error from 0.180 to 0.150 and mean external negative log-likelihood from 0.848 to 0.682. Conclusions: This study establishes a reproducible benchmark for evaluating breast ultrasound AI under dataset shift, with explicit attention to patient-level leakage control, external validity, and reliability of predicted probabilities.

Institutions

Publication Details

Journal
Diagnostics
Published
2026-05-19
DOI
https://doi.org/10.3390/diagnostics16101537
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Breast Ultrasound AI Under Dataset Shift: A Patient-Leakage-Aware Benchmark

Diagnostics
Ultrasound Imaging and Elastography
article

Breast Ultrasound AI Under Dataset Shift: A Patient-Leakage-Aware Benchmark

article en

Abstract

Background: Artificial intelligence (AI) has shown promise in breast ultrasound image analysis, but most evidence still comes from single-dataset studies. Clinical translation requires evaluation under heterogeneous acquisition and curation conditions. This study presents a patient-leakage-aware, reproducible benchmark for breast ultrasound AI under dataset shift, with emphasis on external generalization, calibration, and confidence-related behavior. Methods: A reproducible benchmark framework was developed using patient-level splitting, internal testing, pairwise cross-dataset evaluation, whole-image and region-of-interest (ROI) input strategies, calibration analysis, targeted ROI-margin sensitivity analysis, representative explainable AI visualization, and an auxiliary lesion-versus-normal confidence-based analysis. Four public breast ultrasound datasets (BUSI, BUS-UCLM, BUS-BRA, and BrEaST) were harmonized for a primary benign-versus-malignant lesion classification task. Normal images were excluded from the primary endpoint and used only in auxiliary analyses when sufficient numbers were available. Results: Cross-dataset testing was weaker on average than internal testing, with mean raw AUROC decreasing from 0.801 to 0.719 and mean balanced accuracy from 0.723 to 0.635. ROI input improved external performance, especially for the vision transformer, increasing mean external AUROC from 0.666 to 0.805 and mean external balanced accuracy from 0.594 to 0.713 relative to whole-image input. Temperature scaling improved calibration-related metrics, reducing mean external expected calibration error from 0.180 to 0.150 and mean external negative log-likelihood from 0.848 to 0.682. Conclusions: This study establishes a reproducible benchmark for evaluating breast ultrasound AI under dataset shift, with explicit attention to patient-level leakage control, external validity, and reliability of predicted probabilities.

DiagnosticsVol. 16(10)
Reykjavík University (IS)
Gender equality
Openalex Percentile: Top 5%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.