Visual and Patient-Reported Outcomes After Bilateral Implantation of Two Enhanced Monofocal IOLs

Background/Objectives: Enhanced monofocal intraocular lenses (IOLs) aim to extend functional vision into the intermediate range while preserving the distance visual quality of standard monofocal aspheric lenses. This study compared the clinical and patient-reported outcomes of two enhanced monofocal IOLs, TECNIS Eyhance™ and Evolux™, and characterised the anterior surface profile of the Evolux™ optic. Methods: This single-centre, retrospective comparative case series included consecutive patients who received bilateral implantation of either Evolux™ or TECNIS Eyhance™ between February and July 2023. Primary outcomes were monocular uncorrected and distance-corrected intermediate visual acuity (UIVA, DCIVA). Secondary outcomes included monocular and binocular distance and near visual acuity, binocular intermediate visual acuity, spherical equivalent and patient-reported outcomes assessed using the Revised Heidelberg Daily Task Evaluation (DATE) questionnaire. Equivalence testing, Welch’s t-test, and covariate-adjusted ANCOVA were performed. Anterior surface profilometry of the Evolux™ IOL was conducted using an optical profilometer. Results: A total of 44 patients were included, 14 in the Evolux™ group and 30 in the TECNIS Eyhance™ group. Monocular and binocular UIVA and DCIVA were statistically equivalent between groups (TOST p = 0.028, 0.016, 0.008, and 0.005, respectively). Monocular and binocular distance outcomes were likewise equivalent. Binocular distance-corrected near visual acuity was significantly better in the Evolux™ group (0.164 ± 0.084 vs. 0.233 ± 0.112 logMAR; p = 0.030; Cohen’s d = 0.661), without a corresponding monocular difference. This isolated finding should be interpreted cautiously given the exploratory, multiple-outcome analysis and because it did not retain statistical significance after covariate adjustment for baseline biometric imbalances. Conclusions: In this exploratory study, both IOLs showed no statistically significant differences in intermediate and distance visual outcomes at one month after second eye surgery. The unadjusted binocular near vision finding for Evolux™, which did not retain significance after covariate adjustment, warrants further investigation in prospective, adequately powered, biometrically balanced studies.

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-05-19
DOI
https://doi.org/10.3390/jcm15103904
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual and Patient-Reported Outcomes After Bilateral Implantation of Two Enhanced Monofocal IOLs

Journal of Clinical Medicine
Ophthalmology and Visual Impairment Studies
article

Visual and Patient-Reported Outcomes After Bilateral Implantation of Two Enhanced Monofocal IOLs

article en

Abstract

Background/Objectives: Enhanced monofocal intraocular lenses (IOLs) aim to extend functional vision into the intermediate range while preserving the distance visual quality of standard monofocal aspheric lenses. This study compared the clinical and patient-reported outcomes of two enhanced monofocal IOLs, TECNIS Eyhance™ and Evolux™, and characterised the anterior surface profile of the Evolux™ optic. Methods: This single-centre, retrospective comparative case series included consecutive patients who received bilateral implantation of either Evolux™ or TECNIS Eyhance™ between February and July 2023. Primary outcomes were monocular uncorrected and distance-corrected intermediate visual acuity (UIVA, DCIVA). Secondary outcomes included monocular and binocular distance and near visual acuity, binocular intermediate visual acuity, spherical equivalent and patient-reported outcomes assessed using the Revised Heidelberg Daily Task Evaluation (DATE) questionnaire. Equivalence testing, Welch’s t-test, and covariate-adjusted ANCOVA were performed. Anterior surface profilometry of the Evolux™ IOL was conducted using an optical profilometer. Results: A total of 44 patients were included, 14 in the Evolux™ group and 30 in the TECNIS Eyhance™ group. Monocular and binocular UIVA and DCIVA were statistically equivalent between groups (TOST p = 0.028, 0.016, 0.008, and 0.005, respectively). Monocular and binocular distance outcomes were likewise equivalent. Binocular distance-corrected near visual acuity was significantly better in the Evolux™ group (0.164 ± 0.084 vs. 0.233 ± 0.112 logMAR; p = 0.030; Cohen’s d = 0.661), without a corresponding monocular difference. This isolated finding should be interpreted cautiously given the exploratory, multiple-outcome analysis and because it did not retain statistical significance after covariate adjustment for baseline biometric imbalances. Conclusions: In this exploratory study, both IOLs showed no statistically significant differences in intermediate and distance visual outcomes at one month after second eye surgery. The unadjusted binocular near vision finding for Evolux™, which did not retain significance after covariate adjustment, warrants further investigation in prospective, adequately powered, biometrically balanced studies.

Journal of Clinical MedicineVol. 15(10)
University of Udine (IT), University of Trieste (IT)
Openalex Percentile: Top 5%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.