Analytical Imprecision and Reference Change Values for Longitudinal Monitoring of NCD-Related Biochemical Analytes

Background: Internal quality control (IQC) data offers continuous insight into analytical performance under routine conditions. This study evaluated IQC practices and long-term analytical imprecision (CVa) across primary healthcare laboratories to derive analyte-specific reference change values (RCVs) for non-communicable disease (NCD) monitoring. Methods: A 22-month retrospective analysis of IQC data was conducted across 29 primary healthcare laboratories using 32 analytical units (Beckman Coulter AU480) in Malaysian primary healthcare. Six analytes were assessed: glucose, creatinine, total cholesterol, triglycerides, HDL cholesterol, and ALT. CVa was estimated using median and 90th percentile (P90) coefficients of variation across two concentration levels. RCVs were calculated at 95% probability (Z = 1.96) by integrating observed CVa with within-subject biological variation (CVi) from EFLM databases. Results: IQC testing was highly standardized (median: 20 measurements/month). Long-term data showed stable, concentration-dependent imprecision. Median CVa was lowest for glucose and lipids (1.7–1.9%) but higher for ALT (3.79%) and creatinine (3.52%) at Level 1. Derived RCV ranged from 14% (glucose) to 55.1% (triglycerides), with CVi being the dominant contributor to RCV magnitude for most analytes. Conclusions: Long-term routine IQC data provide an analytically realistic foundation for deriving RCV in primary healthcare by reflecting real-world performance. Applying these RCV supports evidence-based interpretation of serial results, enhancing NCD monitoring by distinguishing true physiological change from analytical and biological noise.

Institutions

Publication Details

Journal
Diagnostics
Published
2026-05-18
DOI
https://doi.org/10.3390/diagnostics16101532
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Imprecision and Reference Change Values for Longitudinal Monitoring of NCD-Related Biochemical Analytes

Diagnostics
Clinical Laboratory Practices and Quality Control
article

Analytical Imprecision and Reference Change Values for Longitudinal Monitoring of NCD-Related Biochemical Analytes

article en

Abstract

Background: Internal quality control (IQC) data offers continuous insight into analytical performance under routine conditions. This study evaluated IQC practices and long-term analytical imprecision (CVa) across primary healthcare laboratories to derive analyte-specific reference change values (RCVs) for non-communicable disease (NCD) monitoring. Methods: A 22-month retrospective analysis of IQC data was conducted across 29 primary healthcare laboratories using 32 analytical units (Beckman Coulter AU480) in Malaysian primary healthcare. Six analytes were assessed: glucose, creatinine, total cholesterol, triglycerides, HDL cholesterol, and ALT. CVa was estimated using median and 90th percentile (P90) coefficients of variation across two concentration levels. RCVs were calculated at 95% probability (Z = 1.96) by integrating observed CVa with within-subject biological variation (CVi) from EFLM databases. Results: IQC testing was highly standardized (median: 20 measurements/month). Long-term data showed stable, concentration-dependent imprecision. Median CVa was lowest for glucose and lipids (1.7–1.9%) but higher for ALT (3.79%) and creatinine (3.52%) at Level 1. Derived RCV ranged from 14% (glucose) to 55.1% (triglycerides), with CVi being the dominant contributor to RCV magnitude for most analytes. Conclusions: Long-term routine IQC data provide an analytically realistic foundation for deriving RCV in primary healthcare by reflecting real-world performance. Applying these RCV supports evidence-based interpretation of serial results, enhancing NCD monitoring by distinguishing true physiological change from analytical and biological noise.

DiagnosticsVol. 16(10)
Institute for Medical Research (MY), Jabatan Perkhidmatan Awam Malaysia (MY)
Openalex Percentile: Top 5%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analytical Imprecision and Reference Change Values for Longitudinal Monitoring of NCD-Related Biochemical Analytes · Diagnostics (2026) | TGRS Research Map | TGRS