Free-form shape optimization of a U-shaped Coriolis Mass Flow Meter for enhanced measurement sensitivity

Coriolis Mass Flow Meters (CMFs) directly measure mass flow rate through tube deformation induced by Coriolis forces. This paper presents a high-fidelity, physics-based shape optimization framework to enhance the sensitivity of a U-shaped CMF while preserving its drive-mode frequency. A free-form approach is employed, treating all finite element nodes as design variables to enable an unbiased exploration of the geometric design space. A static mode-consistent torsional surrogate loading is introduced to mimic the deformation pattern of the Coriolis mode without requiring fully coupled high-fidelity fluid–structure interaction (FSI) simulations. The optimization is carried out using adjoint-based sensitivities, gradient-projection constraint handling, and vertex morphing with Helmholtz-type filtering within the ShapeOptimizationApplication of Kratos Multiphysics . The optimized design achieves about a 105% increase in relative sensors deformation while maintaining the drive frequency at 108.72 Hz. FSI-based verification confirms a corresponding increase in actual phase-shift. The resulting geometry exhibits localized ovalization and a transition toward a π -like shape. The proposed framework provides an efficient approach to sensitivity-driven CMF design, demonstrated here for a U-shaped measuring tube, with particular relevance for low-flow gas and hydrogen applications. • A free-form shape optimization framework is developed for Coriolis mass flow meters. • Eigenfrequency-based optimization is employed to enhance measurement sensitivity. • A static surrogate load reproduces the relevant torsional deformation pattern without full FSI. • Adjoint sensitivities and vertex morphing enable large-scale node-based optimization. • The optimized design achieves a significant increase in relative sensor deformation.

Institutions

Publication Details

Journal
Flow Measurement and Instrumentation
Published
2026-05-19
DOI
https://doi.org/10.1016/j.flowmeasinst.2026.103408
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Free-form shape optimization of a U-shaped Coriolis Mass Flow Meter for enhanced measurement sensitivity

Flow Measurement and Instrumentation
Flow Measurement and Analysis
article

Free-form shape optimization of a U-shaped Coriolis Mass Flow Meter for enhanced measurement sensitivity

article en

Abstract

Coriolis Mass Flow Meters (CMFs) directly measure mass flow rate through tube deformation induced by Coriolis forces. This paper presents a high-fidelity, physics-based shape optimization framework to enhance the sensitivity of a U-shaped CMF while preserving its drive-mode frequency. A free-form approach is employed, treating all finite element nodes as design variables to enable an unbiased exploration of the geometric design space. A static mode-consistent torsional surrogate loading is introduced to mimic the deformation pattern of the Coriolis mode without requiring fully coupled high-fidelity fluid–structure interaction (FSI) simulations. The optimization is carried out using adjoint-based sensitivities, gradient-projection constraint handling, and vertex morphing with Helmholtz-type filtering within the ShapeOptimizationApplication of Kratos Multiphysics . The optimized design achieves about a 105% increase in relative sensors deformation while maintaining the drive frequency at 108.72 Hz. FSI-based verification confirms a corresponding increase in actual phase-shift. The resulting geometry exhibits localized ovalization and a transition toward a π -like shape. The proposed framework provides an efficient approach to sensitivity-driven CMF design, demonstrated here for a U-shaped measuring tube, with particular relevance for low-flow gas and hydrogen applications. • A free-form shape optimization framework is developed for Coriolis mass flow meters. • Eigenfrequency-based optimization is employed to enhance measurement sensitivity. • A static surrogate load reproduces the relevant torsional deformation pattern without full FSI. • Adjoint sensitivities and vertex morphing enable large-scale node-based optimization. • The optimized design achieves a significant increase in relative sensor deformation.

Flow Measurement and InstrumentationVol. 111
Zhejiang Lab (CN), Technical University of Munich (DE)
Openalex Percentile: Top 8%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.