Residents versus experts in interpreting standard Scheimpflug imaging for the diagnosis of keratoconus

Purpose To evaluate the diagnostic performance of final-year ophthalmology residents in classifying keratoconus using standard Scheimpflug corneal tomography and to compare their accuracy to that of experienced corneal specialists. Design Prospective, investigator-initiated, multicenter observational study. Methods Five final-year residents assessed 1,239 anonymized Pentacam HR (Oculus GmbH, Germany) quad-map outputs, categorized as normal, suspect keratoconus, or keratoconus, previously obtained from 620 pediatric patients in a prior population-based imaging study. Two corneal experts independently established the reference standard. Residents rated their diagnostic confidence using Likert scales. Agreement was quantified using Cohen's kappa (κ) and Fleiss's κ. Results Resident-to-expert agreement ranged from Cohen's κ = 0.031 to 0.324 (slight to fair). Overall inter-rater reliability across all raters was slight, Fleiss's κ = 0.088. Four residents rated their diagnostic skill as neutral; one rated it as poor. Self-assessed competence relative to peers was rated as neutral by three residents and good by two. Conclusions Final-year ophthalmology residents showed limited agreement with expert graders when interpreting Scheimpflug images. The alignment between self-assessed confidence and measured diagnostic performance highlights a potential educational gap in image-based diagnosis of ectatic corneal disease. These findings support the need for competency-based curricular enhancements, including image interpretation benchmarks, expert-guided calibration sessions, and simulation-based learning modules, aiming to improve diagnostic accuracy and support earlier detection of keratoconus. Further multicenter studies are needed to validate these results and guide national and international training strategies.

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2026-05-19
DOI
https://doi.org/10.1177/11206721261452041
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Residents versus experts in interpreting standard Scheimpflug imaging for the diagnosis of keratoconus

European Journal of Ophthalmology
Corneal surgery and disorders
article

Residents versus experts in interpreting standard Scheimpflug imaging for the diagnosis of keratoconus

article en

Abstract

Purpose To evaluate the diagnostic performance of final-year ophthalmology residents in classifying keratoconus using standard Scheimpflug corneal tomography and to compare their accuracy to that of experienced corneal specialists. Design Prospective, investigator-initiated, multicenter observational study. Methods Five final-year residents assessed 1,239 anonymized Pentacam HR (Oculus GmbH, Germany) quad-map outputs, categorized as normal, suspect keratoconus, or keratoconus, previously obtained from 620 pediatric patients in a prior population-based imaging study. Two corneal experts independently established the reference standard. Residents rated their diagnostic confidence using Likert scales. Agreement was quantified using Cohen's kappa (κ) and Fleiss's κ. Results Resident-to-expert agreement ranged from Cohen's κ = 0.031 to 0.324 (slight to fair). Overall inter-rater reliability across all raters was slight, Fleiss's κ = 0.088. Four residents rated their diagnostic skill as neutral; one rated it as poor. Self-assessed competence relative to peers was rated as neutral by three residents and good by two. Conclusions Final-year ophthalmology residents showed limited agreement with expert graders when interpreting Scheimpflug images. The alignment between self-assessed confidence and measured diagnostic performance highlights a potential educational gap in image-based diagnosis of ectatic corneal disease. These findings support the need for competency-based curricular enhancements, including image interpretation benchmarks, expert-guided calibration sessions, and simulation-based learning modules, aiming to improve diagnostic accuracy and support earlier detection of keratoconus. Further multicenter studies are needed to validate these results and guide national and international training strategies.

European Journal of Ophthalmology
University of Geneva (CH), University of Bern (CH), University of Zurich (CH), Kantonsspital St. Gallen (CH), University Hospital of Bern (CH), King Saud University (SA), Cleveland Clinic Lerner College of Medicine (US), University Hospital of Zurich (CH), The California Eye Institute (US), ELZA Institute (CH), National Cooperative for the Disposal of Radioactive Waste (Switzerland) (CH), New York University (US), Case Western Reserve University (US)
No poverty
Openalex Percentile: Top 5%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.