Preloaded vs manually loaded intraocular lens delivery failure modes: an analysis of Food and Drug Administration device reports

Purpose: To compare reported intraoperative failure-mode profiles between preloaded and manually loaded intraocular lens (IOL) delivery systems using U.S. Food and Drug Administration (FDA) device reports. Setting: FDA Manufacturer and User Facility Device Experience (MAUDE) database, United States. Design: Retrospective cross-sectional study. Methods: MAUDE reports from January 1, 2016 through December 31, 2025 were reviewed. Reports describing intraoperative IOL loading, delivery, or positioning issues were included when injector type was specified. Structured MAUDE fields served as the primary data source, and free-text narratives were analyzed using automated natural language processing to supplement classification when consistent with structured fields. Comparisons were performed using within-group proportions, and multivariable logistic regression estimated adjusted odds ratios (aORs) controlling for report year, manufacturer, lens platform, and reporting entity. Results: Of 57,435 FDA device reports, 14,460 intraoperative reports met inclusion criteria; 10,567 (73.1%) involved preloaded systems and 3,893 (26.9%) manually loaded systems. Manually loaded systems showed higher reporting of IOL damage (66.0% vs 45.4%; aOR 3.06, 95% CI 2.78–3.37; p<0.001) and loading issues (aOR 5.53, 95% CI 3.99–7.66; p<0.001). Preloaded systems showed higher reporting of delivery failures (40.5% vs 21.8%; aOR 3.91, 95% CI 3.51–4.35; p<0.001), lens positioning issues (aOR 1.27, 95% CI 1.01–1.62; p=0.041), and material or optics abnormalities (aOR 3.53, 95% CI 1.96–6.35; p<0.001). Conclusions: Preloaded and manually loaded IOL delivery systems demonstrated distinct failure-mode profiles within FDA device reports. These findings characterized reporting patterns rather than population-level risk and may inform device design and post-market surveillance priorities.

Institutions

Publication Details

Journal
Journal of Cataract & Refractive Surgery
Published
2026-05-18
DOI
https://doi.org/10.1097/j.jcrs.0000000000001977
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preloaded vs manually loaded intraocular lens delivery failure modes: an analysis of Food and Drug Administration device reports

Journal of Cataract & Refractive Surgery
Intraocular Surgery and Lenses
article

Preloaded vs manually loaded intraocular lens delivery failure modes: an analysis of Food and Drug Administration device reports

article en

Abstract

Purpose: To compare reported intraoperative failure-mode profiles between preloaded and manually loaded intraocular lens (IOL) delivery systems using U.S. Food and Drug Administration (FDA) device reports. Setting: FDA Manufacturer and User Facility Device Experience (MAUDE) database, United States. Design: Retrospective cross-sectional study. Methods: MAUDE reports from January 1, 2016 through December 31, 2025 were reviewed. Reports describing intraoperative IOL loading, delivery, or positioning issues were included when injector type was specified. Structured MAUDE fields served as the primary data source, and free-text narratives were analyzed using automated natural language processing to supplement classification when consistent with structured fields. Comparisons were performed using within-group proportions, and multivariable logistic regression estimated adjusted odds ratios (aORs) controlling for report year, manufacturer, lens platform, and reporting entity. Results: Of 57,435 FDA device reports, 14,460 intraoperative reports met inclusion criteria; 10,567 (73.1%) involved preloaded systems and 3,893 (26.9%) manually loaded systems. Manually loaded systems showed higher reporting of IOL damage (66.0% vs 45.4%; aOR 3.06, 95% CI 2.78–3.37; p<0.001) and loading issues (aOR 5.53, 95% CI 3.99–7.66; p<0.001). Preloaded systems showed higher reporting of delivery failures (40.5% vs 21.8%; aOR 3.91, 95% CI 3.51–4.35; p<0.001), lens positioning issues (aOR 1.27, 95% CI 1.01–1.62; p=0.041), and material or optics abnormalities (aOR 3.53, 95% CI 1.96–6.35; p<0.001). Conclusions: Preloaded and manually loaded IOL delivery systems demonstrated distinct failure-mode profiles within FDA device reports. These findings characterized reporting patterns rather than population-level risk and may inform device design and post-market surveillance priorities.

Journal of Cataract & Refractive Surgery
Mayo Clinic (US), University of Helsinki (FI), Kymenlaakson keskussairaala (FI)
Openalex Percentile: Top 4%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.