Evaluation of the impact of toothbrush wear on artificial plaque removal efficacy

This study evaluated the artificial plaque removal efficacy and wear patterns of three high-density, ultrasoft toothbrushes with polyester filaments (standard, small, and large head sizes) after simulated long-term use. A 3D-printed jaw model and artificial teeth were used, and brushing tests corresponding to 3 months (3 M) and 6 months (6 M) of use were performed. The wear index (WI) was calculated, and morphological changes of the filament tips were examined using a digital microscope. The artificial plaque retention rate was then measured for new brushes (Control), 3 M, and 6 M specimens. In the small-head toothbrush, the artificial plaque retention rate significantly increased after 6 M compared with the control and 3 M. In contrast, no significant differences were observed across usage periods in the standard- and large-head toothbrushes. The WI increased over time in all toothbrushes, with significantly higher values at 3 M and 6 M in the small-head group. Flattening of the filament tips was observed with increasing simulated use. These findings suggest that high-density toothbrushes with an appropriate head size can maintain artificial plaque removal efficacy for up to 3 months, whereas head size influences cleaning performance and wear characteristics after prolonged use.

Institutions

Publication Details

Journal
European Journal Of Oral Sciences
Published
2026-05-18
DOI
https://doi.org/10.1111/eos.70109
Primary Topic
Oral microbiology and periodontitis research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the impact of toothbrush wear on artificial plaque removal efficacy

European Journal Of Oral Sciences
Oral microbiology and periodontitis research
article

Evaluation of the impact of toothbrush wear on artificial plaque removal efficacy

article en

Abstract

This study evaluated the artificial plaque removal efficacy and wear patterns of three high-density, ultrasoft toothbrushes with polyester filaments (standard, small, and large head sizes) after simulated long-term use. A 3D-printed jaw model and artificial teeth were used, and brushing tests corresponding to 3 months (3 M) and 6 months (6 M) of use were performed. The wear index (WI) was calculated, and morphological changes of the filament tips were examined using a digital microscope. The artificial plaque retention rate was then measured for new brushes (Control), 3 M, and 6 M specimens. In the small-head toothbrush, the artificial plaque retention rate significantly increased after 6 M compared with the control and 3 M. In contrast, no significant differences were observed across usage periods in the standard- and large-head toothbrushes. The WI increased over time in all toothbrushes, with significantly higher values at 3 M and 6 M in the small-head group. Flattening of the filament tips was observed with increasing simulated use. These findings suggest that high-density toothbrushes with an appropriate head size can maintain artificial plaque removal efficacy for up to 3 months, whereas head size influences cleaning performance and wear characteristics after prolonged use.

European Journal Of Oral Sciences
Asahi University (JP), King's College London (GB)
Openalex Percentile: Top 5%
Oral microbiology and periodontitis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.