Scan Density Matters: Reproducibility of AI-Derived OCT Biomarkers in Diabetic Macular Edema

Purpose: To determine how optical coherence tomography (OCT) scan density affects quantification of artificial intelligence (AI)-derived structural biomarkers in diabetic macular edema (DME) and to identify density thresholds beyond which biomarker fidelity is compromised. Methods: In this cross-sectional study, 401 DME eyes underwent three same-session OCT acquisitions using 97-, 49-, and 25-B-scan raster protocols on a single device. A CE-certified deep learning pipeline quantified intraretinal fluid (IRF) volume, subretinal fluid (SRF) volume, inflammatory hyperreflective foci (I-HRF), and photoreceptor integrity metrics. Linear mixed-effects models assessed density effects, Bland-Altman analyses quantified fixed and proportional bias, and volumetric thresholds were computed for deviations beyond ±0.10 mm³. Acquisition efficiency integrated biomarker variability and scan time. Results: A total of 9624 biomarker measurements were analyzed with >98% completeness. SRF volume, I-HRF counts, and photoreceptor integrity metrics were stable across scan densities. IRF volume was density-dependent: the 25-scan protocol overestimated IRF relative to 97- and 49-scan acquisitions (mean bias -0.077 and -0.079 mm³; both P < 0.001), whereas 97- and 49-scan measurements were interchangeable. Overestimation increased with fluid burden (IRF threshold ∼1.1 mm³). Although the 25-scan protocol was fastest (10.7 seconds vs. 23.6 seconds and 50.3 seconds), the 49-scan protocol provided the best balance between speed and precision. Conclusions: Most AI-derived OCT biomarkers in DME are robust to reduced scan density, but IRF volume shows increasing error with undersampling. Higher-density scans should be reserved when precise fluid quantification is required. Translational Relevance: Scan density materially influences AI-derived IRF quantification. Identifying practical acquisition thresholds enables protocol standardization while reducing imaging burden in clinical practice and trials.

Institutions

Publication Details

Journal
Translational Vision Science & Technology
Published
2026-05-19
DOI
https://doi.org/10.1167/tvst.15.5.12
Primary Topic
Retinal Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scan Density Matters: Reproducibility of AI-Derived OCT Biomarkers in Diabetic Macular Edema

Translational Vision Science & Technology
Retinal Diseases and Treatments
article

Scan Density Matters: Reproducibility of AI-Derived OCT Biomarkers in Diabetic Macular Edema

article en

Abstract

Purpose: To determine how optical coherence tomography (OCT) scan density affects quantification of artificial intelligence (AI)-derived structural biomarkers in diabetic macular edema (DME) and to identify density thresholds beyond which biomarker fidelity is compromised. Methods: In this cross-sectional study, 401 DME eyes underwent three same-session OCT acquisitions using 97-, 49-, and 25-B-scan raster protocols on a single device. A CE-certified deep learning pipeline quantified intraretinal fluid (IRF) volume, subretinal fluid (SRF) volume, inflammatory hyperreflective foci (I-HRF), and photoreceptor integrity metrics. Linear mixed-effects models assessed density effects, Bland-Altman analyses quantified fixed and proportional bias, and volumetric thresholds were computed for deviations beyond ±0.10 mm³. Acquisition efficiency integrated biomarker variability and scan time. Results: A total of 9624 biomarker measurements were analyzed with >98% completeness. SRF volume, I-HRF counts, and photoreceptor integrity metrics were stable across scan densities. IRF volume was density-dependent: the 25-scan protocol overestimated IRF relative to 97- and 49-scan acquisitions (mean bias -0.077 and -0.079 mm³; both P < 0.001), whereas 97- and 49-scan measurements were interchangeable. Overestimation increased with fluid burden (IRF threshold ∼1.1 mm³). Although the 25-scan protocol was fastest (10.7 seconds vs. 23.6 seconds and 50.3 seconds), the 49-scan protocol provided the best balance between speed and precision. Conclusions: Most AI-derived OCT biomarkers in DME are robust to reduced scan density, but IRF volume shows increasing error with undersampling. Higher-density scans should be reserved when precise fluid quantification is required. Translational Relevance: Scan density materially influences AI-derived IRF quantification. Identifying practical acquisition thresholds enables protocol standardization while reducing imaging burden in clinical practice and trials.

Translational Vision Science & TechnologyVol. 15(5)
University of Padua (IT), Vita-Salute San Raffaele University (IT), University of Catania (IT), Iranian Institute for Health Sciences Research (IR), Fondazione G.B. Bietti (IT), Farabi Hospital (IR), Policlinico Universitario di Catania (IT), ORCID (US), Istituti di Ricovero e Cura a Carattere Scientifico (IT), Istituto di Ricovero e Cura a Carattere Scientifico San Raffaele (IT), Tehran University of Medical Sciences (IR)
Openalex Percentile: Top 4%
Retinal Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.