Direct Identification and Quantification of Nanoplastics in Aqueous Environments via Dual-Channel Electrothermal Vaporization-Microplasma-Based Point Discharge-Optical Emission Spectrometry (DC-ETV-μPD-OES)

A miniaturized analytical platform integrating dual-channel electrothermal vaporization-microplasma-based point discharge-optical emission spectrometry (DC-ETV-μPD-OES) has been developed for the direct identification and quantification of nanoplastics (NPs) in aqueous samples. Unlike conventional approaches that rely on time-consuming and potentially loss-inducing pretreatment steps like “filtration-drying”, this system introduces an innovative “evaporation-pyrolysis” dual-channel design, enabling direct introduction and analysis of liquid suspensions. By incorporating a three-way valve and a silica gel drying unit, the platform effectively redirects and removes water vapor, significantly improving plasma stability and analytical reproducibility. Under optimized conditions, the method delivered linear responses (R2 > 0.998) for polystyrene (PS) NPs, poly(methyl methacrylate) (PMMA) NPs, polylactic acid (PLA) NPs, and polyvinyl chloride (PVC) NPs across a concentration range of 5–227 mg C/L, with detection limits between 4.08 and 11.02 mg C/L. Machine-learning-assisted classification─particularly using the k-nearest neighbors (KNN) algorithm─achieved 100% accuracy in polymer discrimination based on spectral fingerprints. Analysis of spiked environmental water samples yielded recoveries (84.6–109.1%), confirming the method’s reliability for real-world applications. This work establishes a portable, low-energy-consumption alternative to conventional laboratory-based techniques, offering a practical and promising tool for on-site screening and quantification of NPs in aquatic environments.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-05-18
DOI
https://doi.org/10.1021/acs.analchem.6c00102
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Identification and Quantification of Nanoplastics in Aqueous Environments via Dual-Channel Electrothermal Vaporization-Microplasma-Based Point Discharge-Optical Emission Spectrometry (DC-ETV-μPD-OES)

Zhengchang Xing, Maoyong Song, Yue Wang, Xinyi Wu et al.
Analytical Chemistry
Plasma Applications and Diagnostics
article

Direct Identification and Quantification of Nanoplastics in Aqueous Environments via Dual-Channel Electrothermal Vaporization-Microplasma-Based Point Discharge-Optical Emission Spectrometry (DC-ETV-μPD-OES)

Zhengchang Xing, Maoyong Song, Yue Wang, Xinyi Wu, Z W Wu, Zhiqiang Tan, Shixiang Gao, Yuqiao Mao, Hongwei Liu, Yan Li, Yongguang Yin, Guibin Jiang
article en

Abstract

A miniaturized analytical platform integrating dual-channel electrothermal vaporization-microplasma-based point discharge-optical emission spectrometry (DC-ETV-μPD-OES) has been developed for the direct identification and quantification of nanoplastics (NPs) in aqueous samples. Unlike conventional approaches that rely on time-consuming and potentially loss-inducing pretreatment steps like “filtration-drying”, this system introduces an innovative “evaporation-pyrolysis” dual-channel design, enabling direct introduction and analysis of liquid suspensions. By incorporating a three-way valve and a silica gel drying unit, the platform effectively redirects and removes water vapor, significantly improving plasma stability and analytical reproducibility. Under optimized conditions, the method delivered linear responses (R2 > 0.998) for polystyrene (PS) NPs, poly(methyl methacrylate) (PMMA) NPs, polylactic acid (PLA) NPs, and polyvinyl chloride (PVC) NPs across a concentration range of 5–227 mg C/L, with detection limits between 4.08 and 11.02 mg C/L. Machine-learning-assisted classification─particularly using the k-nearest neighbors (KNN) algorithm─achieved 100% accuracy in polymer discrimination based on spectral fingerprints. Analysis of spiked environmental water samples yielded recoveries (84.6–109.1%), confirming the method’s reliability for real-world applications. This work establishes a portable, low-energy-consumption alternative to conventional laboratory-based techniques, offering a practical and promising tool for on-site screening and quantification of NPs in aquatic environments.

Analytical Chemistry
Chinese Academy of Sciences (CN), China University of Mining and Technology (CN), State Key Laboratory of Pollution Control and Resource Reuse (CN), Department of the Environment (GB), Culture Resource (EG), Research Center for Eco-Environmental Sciences (CN), University of Chinese Academy of Sciences (CN), Nanjing University (CN)
National Natural Science Foundation of China, Chinese Academy of Sciences, State Key Laboratory of Environmental Chemistry and Ecotoxicology
Clean water and sanitation
Openalex Percentile: Top 5%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.