Agreement of Corvis ST Biomechanical IOP Measurements With Pachymetry-Based Correction Formulas in Patients With Keratoconus: A Comparative Analysis According to Disease Severity

Objectives: To evaluate the agreement of intraocular pressure (IOP) measurements obtained by Corvis ST using biomechanically corrected IOP (bIOP), noncontact tonometry (NCT), and pachymetry-based correction formulas (Ehlers, Shah, Dresden, Spoerl) across different keratoconus severity levels and in comparison with healthy control eyes. Methods: This prospective, cross-sectional study included 77 patients with keratoconus (77 eyes), categorized by severity using Pentacam-based Topographic Keratoconus Classification and 54 healthy control patients. Patients underwent corneal tomography, and IOP was measured with Corvis ST. Uncorrected NCT-IOP (IOPnct), biomechanically corrected IOP (bIOP), and pachymetry-based corrected IOP (Ehlers, Shah, Dresden, Spoerl) were compared. Agreement among methods was assessed using Bland–Altman analysis. Results: The mean patient age was 26.4±7.3 years (59.7% male). NCT consistently underestimated IOP compared with bIOP, while Ehlers (+2.6 mm Hg), Shah (+1.4 mm Hg), and Dresden (+0.7 mm Hg) formulas significantly overestimated ( P <0.001). The Spoerl formula (−0.9 mm Hg) showed no significant difference compared with bIOP ( P =0.209). Bland–Altman analysis confirmed that the Spoerl formula had the smallest bias and narrowest limits of agreement across all keratoconus stages. Differences between methods became more pronounced with increasing severity, particularly evident for Ehlers and Shah formulas. In healthy control eyes, the different IOP estimation methods showed relatively small bias relative to bIOP. Conclusions: Noncontact tonometry significantly underestimates, and common pachymetry-based corrections (Ehlers, Shah, Dresden) tend to overestimate IOP in keratoconic eyes. The Spoerl formula provides IOP values most closely aligned with the Corvis ST bIOP across all keratoconus stages and was the most consistent pachymetric correction method relative to this biomechanically corrected comparator. Agreement between methods was closer in healthy corneas than in keratoconic eyes, supporting the influence of altered corneal biomechanics on tonometric measurements.

Authors

Institutions

Publication Details

Journal
Eye & Contact Lens Science & Clinical Practice
Published
2026-05-18
DOI
https://doi.org/10.1097/icl.0000000000001284
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Agreement of Corvis ST Biomechanical IOP Measurements With Pachymetry-Based Correction Formulas in Patients With Keratoconus: A Comparative Analysis According to Disease Severity

Serhat Ermiş, Ali Ceylan, Burçin Kepez Yıldız, İdil Çelen Arabacı et al.
Eye & Contact Lens Science & Clinical Practice
Corneal surgery and disorders
article

Agreement of Corvis ST Biomechanical IOP Measurements With Pachymetry-Based Correction Formulas in Patients With Keratoconus: A Comparative Analysis According to Disease Severity

Serhat Ermiş, Ali Ceylan, Burçin Kepez Yıldız, İdil Çelen Arabacı, Fahri Onur Aydın, Yusuf Berk Akbaş
article en

Abstract

Objectives: To evaluate the agreement of intraocular pressure (IOP) measurements obtained by Corvis ST using biomechanically corrected IOP (bIOP), noncontact tonometry (NCT), and pachymetry-based correction formulas (Ehlers, Shah, Dresden, Spoerl) across different keratoconus severity levels and in comparison with healthy control eyes. Methods: This prospective, cross-sectional study included 77 patients with keratoconus (77 eyes), categorized by severity using Pentacam-based Topographic Keratoconus Classification and 54 healthy control patients. Patients underwent corneal tomography, and IOP was measured with Corvis ST. Uncorrected NCT-IOP (IOPnct), biomechanically corrected IOP (bIOP), and pachymetry-based corrected IOP (Ehlers, Shah, Dresden, Spoerl) were compared. Agreement among methods was assessed using Bland–Altman analysis. Results: The mean patient age was 26.4±7.3 years (59.7% male). NCT consistently underestimated IOP compared with bIOP, while Ehlers (+2.6 mm Hg), Shah (+1.4 mm Hg), and Dresden (+0.7 mm Hg) formulas significantly overestimated ( P <0.001). The Spoerl formula (−0.9 mm Hg) showed no significant difference compared with bIOP ( P =0.209). Bland–Altman analysis confirmed that the Spoerl formula had the smallest bias and narrowest limits of agreement across all keratoconus stages. Differences between methods became more pronounced with increasing severity, particularly evident for Ehlers and Shah formulas. In healthy control eyes, the different IOP estimation methods showed relatively small bias relative to bIOP. Conclusions: Noncontact tonometry significantly underestimates, and common pachymetry-based corrections (Ehlers, Shah, Dresden) tend to overestimate IOP in keratoconic eyes. The Spoerl formula provides IOP values most closely aligned with the Corvis ST bIOP across all keratoconus stages and was the most consistent pachymetric correction method relative to this biomechanically corrected comparator. Agreement between methods was closer in healthy corneas than in keratoconic eyes, supporting the influence of altered corneal biomechanics on tonometric measurements.

Eye & Contact Lens Science & Clinical Practice
Akdeniz University Hospital (TR), Sağlık Bilimleri Üniversitesi (TR), University of Health Sciences Antigua (AG)
Openalex Percentile: Top 5%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.