Validation of photoplethysmography-derived short-term heart rate variability using a wearable device

Heart rate variability (HRV) reflects cardiac autonomic function and cardiovascular health. While electrocardiography (ECG) remains the gold standard for HRV assessment, photoplethysmography (PPG)-based wearables offer an alternative for monitoring. This study aimed to validate the wrist-worn PPG device Bora band® for short-term HRV assessment against standard ECG and to characterize domain-specific agreement patterns. In this prospective, single-center observational study, 66 participants in sinus rhythm underwent simultaneous high-resolution 12-lead ECG and wrist-based PPG recording for 5 min and 30 s. PPG-derived interbeat intervals were extracted and compared to ECG-derived R-R intervals. Sixteen HRV metrics from time-, frequency-, and non-linear domains were computed for both modalities. Agreement was assessed using biweight mid-correlation (ρ), Cliff's delta (δ), and equivalence testing (TOST). Strong agreement was observed for mean heart rate (ρ = 1.0, δ = 0.104, TOST p < 0.001), standard deviation of normal-to-normal intervals (ρ = 0.98, δ = 0.037, TOST p = 0.003), deceleration capacity of heart rate (ρ = 0.95, δ = 0.071, TOST p = 0.014), coefficient of variation of normal-to-normal intervals (ρ = 0.98, δ = 0.035, TOST p = 0.002) and Poincaré Plot standard deviation 2 (ρ = 0.99, δ = 0.074, TOST p < 0.001). Moderate agreement was noted for long-term fractal scaling exponent and very low-, low- and high-frequency power. Weaker agreement appeared for short-term variability and entropy metrics. Bland-Altman analysis indicated minimal bias without systematic error. Under controlled resting conditions, wrist-based PPG provides reliable HRV indices compared with ECG-derived HRV. These findings support the use of selected PPG-derived HRV parameters for short-term assessment in clinical settings. Further validation in real-world settings will be necessary.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-18
DOI
https://doi.org/10.1038/s41598-026-52700-7
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of photoplethysmography-derived short-term heart rate variability using a wearable device

Florian Tilquin, Yann Le Guillou, Benjamin Speich, Peter Hämmerle et al.
Scientific Reports
Non-Invasive Vital Sign Monitoring
article

Validation of photoplethysmography-derived short-term heart rate variability using a wearable device

Florian Tilquin, Yann Le Guillou, Benjamin Speich, Peter Hämmerle, Emmanuel Dervieux, Christine S. Zuern, Niklaus D. Labhardt, Emel Kaplan, Matthias Briel, Maximilian Felkel, Felix Mahfoud, Qian Zhou
article en

Abstract

Heart rate variability (HRV) reflects cardiac autonomic function and cardiovascular health. While electrocardiography (ECG) remains the gold standard for HRV assessment, photoplethysmography (PPG)-based wearables offer an alternative for monitoring. This study aimed to validate the wrist-worn PPG device Bora band® for short-term HRV assessment against standard ECG and to characterize domain-specific agreement patterns. In this prospective, single-center observational study, 66 participants in sinus rhythm underwent simultaneous high-resolution 12-lead ECG and wrist-based PPG recording for 5 min and 30 s. PPG-derived interbeat intervals were extracted and compared to ECG-derived R-R intervals. Sixteen HRV metrics from time-, frequency-, and non-linear domains were computed for both modalities. Agreement was assessed using biweight mid-correlation (ρ), Cliff's delta (δ), and equivalence testing (TOST). Strong agreement was observed for mean heart rate (ρ = 1.0, δ = 0.104, TOST p < 0.001), standard deviation of normal-to-normal intervals (ρ = 0.98, δ = 0.037, TOST p = 0.003), deceleration capacity of heart rate (ρ = 0.95, δ = 0.071, TOST p = 0.014), coefficient of variation of normal-to-normal intervals (ρ = 0.98, δ = 0.035, TOST p = 0.002) and Poincaré Plot standard deviation 2 (ρ = 0.99, δ = 0.074, TOST p < 0.001). Moderate agreement was noted for long-term fractal scaling exponent and very low-, low- and high-frequency power. Weaker agreement appeared for short-term variability and entropy metrics. Bland-Altman analysis indicated minimal bias without systematic error. Under controlled resting conditions, wrist-based PPG provides reliable HRV indices compared with ECG-derived HRV. These findings support the use of selected PPG-derived HRV parameters for short-term assessment in clinical settings. Further validation in real-world settings will be necessary.

Scientific Reports
University of Basel (CH), University Hospital of Basel (CH), Hospital Base (CL), JCP Connect (France) (FR)
Universitätsspital Basel, Schweizerische Herzstiftung
Gender equality
Openalex Percentile: Top 9%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.