4% Tetrasodium EDTA to Prevent Central Venous Access Device–Associated Complications

Importance Use of central venous access devices (CVADs) can result in catheter-associated bloodstream infection, catheter occlusion, and catheter-related venous thrombosis. EDTA is a potent anticoagulant, antimicrobial, and antibiofilm agent that can be instilled into inactive CVAD ports as a locking fluid to decrease the risk of infection and maintain patency. Objective To determine whether a 4% tetrasodium EDTA (t-EDTA) locking fluid reduces CVAD-associated infections, occlusions, and thrombolytic use in adults treated in an intensive care unit (ICU). Design, Setting, and Participants Pragmatic, triple-blind, multicenter, cluster-randomized crossover trial including patients older than 18 years in the ICU with a CVAD in place and at least 1 lumen not in use. The trial was conducted in 6 Canadian hospitals (3 community hospitals and 3 academic centers). The first patient was enrolled on March 22, 2022, and the date of last follow-up occurred on September 25, 2024. Interventions The ICUs were randomized to use prefilled, identical, masked syringes containing 2.5 mL of t-EDTA (intervention) or control locking fluid (saline or 4% citrate for hemodialysis lines) for all trial participants over a 3.5-month period. After a 1-month follow-up period, ICUs crossed over to the opposing treatment group for another 3.5 months, with a subsequent 1-month follow-up. Main Outcomes and Measures The primary outcome was a composite incidence rate of CVAD-associated bloodstream infection, catheter occlusion requiring alteplase use, and/or catheter removal due to occlusion. Three of the 8 prespecified secondary outcomes included incidence rates of each component of the primary outcome separately. Results Of the 1574 eligible patients, 1468 (mean age, 60 [SD, 16.0] years; 37.7% female) were included in the analysis (696 receiving t-EDTA and 772 receiving control). The incidence rate of primary outcome events was 13.1 per 1000 catheter-days (74 events) in the t-EDTA group vs 19.9 per 1000 catheter-days (126 events) in the control group. In adjusted multivariate analysis, the incidence rate of the composite outcome was lower among patients receiving t-EDTA vs control (rate ratio, 0.68; 95% CI, 0.47-0.96; P = .03). Among the 3 components of the primary outcome, only the secondary outcome of CVAD occlusion requiring administration of alteplase significantly differed between the groups, with lower rates in the t-EDTA group vs control (66 vs 112; incidence rate, 11.67 and 17.73 per 1000 catheter-days, respectively; rate ratio, 0.66; 95% CI, 0.46-0.96). Conclusions and Relevance Compared with control locking solution, use of 4% t-EDTA locking solution for CVADs reduced the incidence of a composite outcome of CVAD-associated bloodstream infection, catheter occlusion requiring alteplase use, and catheter removal due to occlusion among adult patients in the ICU. Trial Registration ClinicalTrials.gov Identifier: NCT04548713

Authors

Institutions

Publication Details

Journal
JAMA
Published
2026-05-18
DOI
https://doi.org/10.1001/jama.2026.6025
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

4% Tetrasodium EDTA to Prevent Central Venous Access Device–Associated Complications

E Rohrs, Hubert Wong, Anish R. Mitra, S Reynolds et al.
JAMA
Central Venous Catheters and Hemodialysis
article

4% Tetrasodium EDTA to Prevent Central Venous Access Device–Associated Complications

E Rohrs, Hubert Wong, Anish R. Mitra, S Reynolds, Marlena Ornowska, Gloria Vázquez‐Grande, Jessica Wittmann, Gordon Wood, David Forrest, Sandra Blitz, Wesley Jang, Daniel Ovakim
article en

Abstract

Importance Use of central venous access devices (CVADs) can result in catheter-associated bloodstream infection, catheter occlusion, and catheter-related venous thrombosis. EDTA is a potent anticoagulant, antimicrobial, and antibiofilm agent that can be instilled into inactive CVAD ports as a locking fluid to decrease the risk of infection and maintain patency. Objective To determine whether a 4% tetrasodium EDTA (t-EDTA) locking fluid reduces CVAD-associated infections, occlusions, and thrombolytic use in adults treated in an intensive care unit (ICU). Design, Setting, and Participants Pragmatic, triple-blind, multicenter, cluster-randomized crossover trial including patients older than 18 years in the ICU with a CVAD in place and at least 1 lumen not in use. The trial was conducted in 6 Canadian hospitals (3 community hospitals and 3 academic centers). The first patient was enrolled on March 22, 2022, and the date of last follow-up occurred on September 25, 2024. Interventions The ICUs were randomized to use prefilled, identical, masked syringes containing 2.5 mL of t-EDTA (intervention) or control locking fluid (saline or 4% citrate for hemodialysis lines) for all trial participants over a 3.5-month period. After a 1-month follow-up period, ICUs crossed over to the opposing treatment group for another 3.5 months, with a subsequent 1-month follow-up. Main Outcomes and Measures The primary outcome was a composite incidence rate of CVAD-associated bloodstream infection, catheter occlusion requiring alteplase use, and/or catheter removal due to occlusion. Three of the 8 prespecified secondary outcomes included incidence rates of each component of the primary outcome separately. Results Of the 1574 eligible patients, 1468 (mean age, 60 [SD, 16.0] years; 37.7% female) were included in the analysis (696 receiving t-EDTA and 772 receiving control). The incidence rate of primary outcome events was 13.1 per 1000 catheter-days (74 events) in the t-EDTA group vs 19.9 per 1000 catheter-days (126 events) in the control group. In adjusted multivariate analysis, the incidence rate of the composite outcome was lower among patients receiving t-EDTA vs control (rate ratio, 0.68; 95% CI, 0.47-0.96; P = .03). Among the 3 components of the primary outcome, only the secondary outcome of CVAD occlusion requiring administration of alteplase significantly differed between the groups, with lower rates in the t-EDTA group vs control (66 vs 112; incidence rate, 11.67 and 17.73 per 1000 catheter-days, respectively; rate ratio, 0.66; 95% CI, 0.46-0.96). Conclusions and Relevance Compared with control locking solution, use of 4% t-EDTA locking solution for CVADs reduced the incidence of a composite outcome of CVAD-associated bloodstream infection, catheter occlusion requiring alteplase use, and catheter removal due to occlusion among adult patients in the ICU. Trial Registration ClinicalTrials.gov Identifier: NCT04548713

JAMA
Providence Health Care (CA), Royal Columbian Hospital (CA), University of British Columbia (CA), Fraser Health (CA), Simon Fraser University (CA), Centre for Advancing Health Outcomes (CA), University of Manitoba (CA)
Good health and well-being
Openalex Percentile: Top 4%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.