Occlusion effects, safety, and clinical prognosis of Watchman and LAmbre occluders in left atrial appendage closure

PURPOSE: This study preformed to investigate the safety and effectiveness of the Watchman and LAmbre occluders in left atrial appendage closure (LAAC) for the prevention of thrombosis and stroke in patients with atrial fibrillation (AF). METHODS: A retrospective analysis was conducted on 93 patients with nonvalvular atrial fibrillation (NVAF) who underwent LAAC at Northern Jiangsu People's Hospital from January 2020 to February 2023. Of these, 48 were implanted with the Watchman occluder and 45 with the LAmbre occluder. RESULTS: Differences in LAA opening diameter and left atrial diameter between groups were statistically significant (P < 0.001, P = 0.012). The complete occlusion rate of the LAA in the Watchman group was 45.83% (22/48), compared to 24.44% (11/45) in the LAmbre group, with a significant difference between groups (P = 0.031 < 0.05). Neither group experienced any transient ischemic attacks, cardiac tamponade, or deaths during the perioperative period. Three-month postoperative CTA check-ups showed no displacement or detachment of occluders in either group. The incidence of residual shunt measured by CTA was significantly lower in the Watchman group than in the LAmbre group. The most common occurrence in both groups was a 1-3 mm peri-device leak (PDL) at the edge of the occluders. One major PDL (≥ 5 mm) occurred in the LAmbre group. Both groups had device-related thrombosis (DRT) on the atrial side of the occluder, all of which were in patients with PDL and disappeared after 3 months of systemic anticoagulation therapy. CONCLUSION: Both the LAmbre and Watchman occluders show high safety and clinical prognosis in LAAC treatment for AF.

Authors

Institutions

Publication Details

Journal
BMC Cardiovascular Disorders
Published
2026-05-18
DOI
https://doi.org/10.1186/s12872-026-05978-4
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Occlusion effects, safety, and clinical prognosis of Watchman and LAmbre occluders in left atrial appendage closure

Renjie Ma, Tianyu Li, Jing Ye, Song Zhang et al.
BMC Cardiovascular Disorders
Atrial Fibrillation Management and Outcomes
article

Occlusion effects, safety, and clinical prognosis of Watchman and LAmbre occluders in left atrial appendage closure

Renjie Ma, Tianyu Li, Jing Ye, Song Zhang, Siyuan Lu, Mingrui Cui
article en

Abstract

PURPOSE: This study preformed to investigate the safety and effectiveness of the Watchman and LAmbre occluders in left atrial appendage closure (LAAC) for the prevention of thrombosis and stroke in patients with atrial fibrillation (AF). METHODS: A retrospective analysis was conducted on 93 patients with nonvalvular atrial fibrillation (NVAF) who underwent LAAC at Northern Jiangsu People's Hospital from January 2020 to February 2023. Of these, 48 were implanted with the Watchman occluder and 45 with the LAmbre occluder. RESULTS: Differences in LAA opening diameter and left atrial diameter between groups were statistically significant (P < 0.001, P = 0.012). The complete occlusion rate of the LAA in the Watchman group was 45.83% (22/48), compared to 24.44% (11/45) in the LAmbre group, with a significant difference between groups (P = 0.031 < 0.05). Neither group experienced any transient ischemic attacks, cardiac tamponade, or deaths during the perioperative period. Three-month postoperative CTA check-ups showed no displacement or detachment of occluders in either group. The incidence of residual shunt measured by CTA was significantly lower in the Watchman group than in the LAmbre group. The most common occurrence in both groups was a 1-3 mm peri-device leak (PDL) at the edge of the occluders. One major PDL (≥ 5 mm) occurred in the LAmbre group. Both groups had device-related thrombosis (DRT) on the atrial side of the occluder, all of which were in patients with PDL and disappeared after 3 months of systemic anticoagulation therapy. CONCLUSION: Both the LAmbre and Watchman occluders show high safety and clinical prognosis in LAAC treatment for AF.

BMC Cardiovascular Disorders
Nantong University (CN), The Affiliated Taizhou People's Hospital of Nanjing Medical University (CN), Northern Jiangsu People's Hospital (CN), Guang’anmen Hospital (CN), Yangzhou University (CN)
Good health and well-being
Openalex Percentile: Top 6%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.