Performance Analysis of an Auxiliary Fan in Underground Coal Mine Ventilation Systems

Mine ventilation is a critical component of underground coal mining operations, ensuring the supply of fresh air and the removal of hazardous gases, dust, and heat. This study focuses on the performance analysis of an auxiliary mine fan in a duct system to understand the relationship between airflow, pressure, and system resistance. Key performance parameters, including static pressure, velocity pressure, and air velocity, were evaluated through experimental data collected from multiple mine scenarios. The study reveals that Mine B achieved the highest airflow of 5.03 m³/s and velocity of 10.0 m/s due to optimal duct diameter and pressure. The findings emphasise that controlling airflow by adjusting fan speed is significantly more energy-efficient than traditional throttling methods.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-05-18
DOI
https://doi.org/10.5281/zenodo.20266530
Primary Topic
Coal Properties and Utilization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of an Auxiliary Fan in Underground Coal Mine Ventilation Systems

Somnath Kumar Rishi, Akash Hembrom, Anjeol Gope, Akash Kumar Mahto et al.
Zenodo (CERN European Organization for Nuclear Research)
Coal Properties and Utilization
article

Performance Analysis of an Auxiliary Fan in Underground Coal Mine Ventilation Systems

Somnath Kumar Rishi, Akash Hembrom, Anjeol Gope, Akash Kumar Mahto, Rahul Yadav, Shivam Parsad
article en

Abstract

Mine ventilation is a critical component of underground coal mining operations, ensuring the supply of fresh air and the removal of hazardous gases, dust, and heat. This study focuses on the performance analysis of an auxiliary mine fan in a duct system to understand the relationship between airflow, pressure, and system resistance. Key performance parameters, including static pressure, velocity pressure, and air velocity, were evaluated through experimental data collected from multiple mine scenarios. The study reveals that Mine B achieved the highest airflow of 5.03 m³/s and velocity of 10.0 m/s due to optimal duct diameter and pressure. The findings emphasise that controlling airflow by adjusting fan speed is significantly more energy-efficient than traditional throttling methods.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 7%
Coal Properties and Utilization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.