Numerical backup protection scheme based on alienation indices of voltage and current measurements practically applied to synchronous generators

Differential current relays are the primary protection for detecting fault disturbances within the protection zone of three-phase synchronous generator stator windings. This paper presents a numerical backup protection scheme, based on the alienation algorithm, which serves as a redundant protection when the main differential current relay fails to isolate stator winding faults. The proposed method quantifies a set of alienation indices derived from fifteen Pearson correlation coefficients, calculated for the three-phase voltages and currents measured at the load terminals of the generator stator windings. A novel set of tripping characteristic curves, formulated from the alienation indices, enables the implementation of secondary protection functions. The method effectively detects fault disturbances and voltage/current imbalance conditions in the three-phase generator signals. The experimental validation is performed using a motor-generator set equipped with voltage and current transformers installed at the generator load terminals. The system hardware is emulated through a DAC and personal computer, while the alienation algorithm is implemented and processed using the LABVIEW software environment. Extensive experimental investigations were carried out to validate the proposed method under various fault scenarios affecting the generator. The results demonstrate the alienation algorithm's notable simplicity, effectiveness, reliability, and efficiency. Quantitatively, the protection scheme achieved security and dependability levels exceeding 99.80%, while its reliability and accuracy surpassed 99.60%. Moreover, the proposed scheme reduces the protection malfunction rate to only 0.37%. Compared to the coherence-based alienation method for analyzing voltage and current signals, the correlation-based alienation method provides superior response speed, improved performance metrics, greater accuracy, and a more reliable assessment of asymmetry and disturbance levels. An alienation tripping-time curve is created for the backup protection scheme, enabling time-delayed tripping under fault conditions, and its operating speed can be flexibly adjusted to meet specific protection requirements.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-18
DOI
https://doi.org/10.1038/s41598-026-51239-x
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical backup protection scheme based on alienation indices of voltage and current measurements practically applied to synchronous generators

R. A. Mahmoud, Mohamed Adel Esmaeel Salama
Scientific Reports
Power Systems Fault Detection
article

Numerical backup protection scheme based on alienation indices of voltage and current measurements practically applied to synchronous generators

R. A. Mahmoud, Mohamed Adel Esmaeel Salama
article en

Abstract

Differential current relays are the primary protection for detecting fault disturbances within the protection zone of three-phase synchronous generator stator windings. This paper presents a numerical backup protection scheme, based on the alienation algorithm, which serves as a redundant protection when the main differential current relay fails to isolate stator winding faults. The proposed method quantifies a set of alienation indices derived from fifteen Pearson correlation coefficients, calculated for the three-phase voltages and currents measured at the load terminals of the generator stator windings. A novel set of tripping characteristic curves, formulated from the alienation indices, enables the implementation of secondary protection functions. The method effectively detects fault disturbances and voltage/current imbalance conditions in the three-phase generator signals. The experimental validation is performed using a motor-generator set equipped with voltage and current transformers installed at the generator load terminals. The system hardware is emulated through a DAC and personal computer, while the alienation algorithm is implemented and processed using the LABVIEW software environment. Extensive experimental investigations were carried out to validate the proposed method under various fault scenarios affecting the generator. The results demonstrate the alienation algorithm's notable simplicity, effectiveness, reliability, and efficiency. Quantitatively, the protection scheme achieved security and dependability levels exceeding 99.80%, while its reliability and accuracy surpassed 99.60%. Moreover, the proposed scheme reduces the protection malfunction rate to only 0.37%. Compared to the coherence-based alienation method for analyzing voltage and current signals, the correlation-based alienation method provides superior response speed, improved performance metrics, greater accuracy, and a more reliable assessment of asymmetry and disturbance levels. An alienation tripping-time curve is created for the backup protection scheme, enabling time-delayed tripping under fault conditions, and its operating speed can be flexibly adjusted to meet specific protection requirements.

Scientific ReportsVol. 16(1)
Misr University for Science and Technology (EG), Helwan University (EG)
Cairo University, Science and Technology Development Fund, Helwan University, Faculty of Engineering and Information Technology, University of Technology Sydney
Openalex Percentile: Top 6%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.