Feasibility of Magnetic Resonance Imaging–Guided Pulmonary Artery Stenting in a Commercial Wide-Bore 0.55-T Scanner

Real-time pulmonary artery (PA) stenting under magnetic resonance imaging (MRI) guidance may eliminate radiation exposure during complex vascular interventions. This study evaluated the feasibility of performing PA stenting in a swine model using a commercially available 0.55-T MRI system with ferumoxytol-enhanced imaging. Ten juvenile pigs underwent attempts at MRI-guided PA stent deployment using stainless-steel balloon-expandable stents. Stenting was successful in 7 animals, with all successes achieved after switching from femoral to external jugular venous access. Real-time gradient echo imaging provided sufficient visualization for catheter navigation, device delivery, and stent deployment. Postdeployment phase contrast imaging demonstrated flow continuity, minimal artifact, and trivial pressure gradients across the stent (0.2 ± 0.12 mm Hg). Peak velocities increased by 21.2 ± 7.0 cm/s distal to the stent, confirming preserved patency. These findings demonstrate the technical feasibility of CMR-guided PA stenting at 0.55-T and support the potential for future radiation-free PA interventions.

Authors

Institutions

Publication Details

Journal
JACC Basic to Translational Science
Published
2026-05-18
DOI
https://doi.org/10.1016/j.jacbts.2026.101562
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of Magnetic Resonance Imaging–Guided Pulmonary Artery Stenting in a Commercial Wide-Bore 0.55-T Scanner

Aimee K. Armstrong, Jason Swinning, Yixuan Liu, David C. Gross et al.
JACC Basic to Translational Science
Cardiac Valve Diseases and Treatments
article

Feasibility of Magnetic Resonance Imaging–Guided Pulmonary Artery Stenting in a Commercial Wide-Bore 0.55-T Scanner

Aimee K. Armstrong, Jason Swinning, Yixuan Liu, David C. Gross, Jianing Pang, Orlando P. Simonetti, Paul Borm, Joshua Krieger, Nathan A. Ooms, Matthew Joseph, Orville Bramwell, John M. Kelly, Axel J. Krafft, Florian Maier, Yingmin Liu, Jesse Roll, Lucien de Mos, Ning Jin
article en

Abstract

Real-time pulmonary artery (PA) stenting under magnetic resonance imaging (MRI) guidance may eliminate radiation exposure during complex vascular interventions. This study evaluated the feasibility of performing PA stenting in a swine model using a commercially available 0.55-T MRI system with ferumoxytol-enhanced imaging. Ten juvenile pigs underwent attempts at MRI-guided PA stent deployment using stainless-steel balloon-expandable stents. Stenting was successful in 7 animals, with all successes achieved after switching from femoral to external jugular venous access. Real-time gradient echo imaging provided sufficient visualization for catheter navigation, device delivery, and stent deployment. Postdeployment phase contrast imaging demonstrated flow continuity, minimal artifact, and trivial pressure gradients across the stent (0.2 ± 0.12 mm Hg). Peak velocities increased by 21.2 ± 7.0 cm/s distal to the stent, confirming preserved patency. These findings demonstrate the technical feasibility of CMR-guided PA stenting at 0.55-T and support the potential for future radiation-free PA interventions.

JACC Basic to Translational ScienceVol. 11(6)
Nationwide Children's Hospital (US), Purdue University West Lafayette (US), MED Institute (US), Cook Research (United States) (US), Cook Medical (United States) (US), Siemens Healthineers (Germany) (DE), The Ohio State University (US)
American Heart Association, National Heart, Lung, and Blood Institute
Openalex Percentile: Top 6%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.