GRU-enhanced S-transform for fault line selection in low-current grounding systems

Fault line selection in small current grounding systems is challenging due to single-phase grounding faults. Existing methods struggle with feature extraction under varying fault conditions and temporal pattern recognition. To address this, we propose the GRU-S Transform Fault Line Selection (GRU-STF) method. This approach combines an enhanced S-transform with adjustable factors for adaptive time–frequency resolution optimization and a multi-scale analysis framework covering three frequency bands. A BP neural network with Gated Recurrent Units captures temporal dependencies, while dynamic sample balancing using K-means clustering addresses sample imbalance and overfitting. Experimental validation on simulation datasets and field data demonstrates that GRU-STF achieves 95.7% accuracy on simulation data and 91.8% on field data, with an average response time of 28 ms, outperforming existing baselines.

Authors

Institutions

Publication Details

Journal
Discover Computing
Published
2026-05-18
DOI
https://doi.org/10.1007/s10791-026-10149-2
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GRU-enhanced S-transform for fault line selection in low-current grounding systems

Liping Wen
Discover Computing
Power Systems Fault Detection
article

GRU-enhanced S-transform for fault line selection in low-current grounding systems

Liping Wen
article en

Abstract

Fault line selection in small current grounding systems is challenging due to single-phase grounding faults. Existing methods struggle with feature extraction under varying fault conditions and temporal pattern recognition. To address this, we propose the GRU-S Transform Fault Line Selection (GRU-STF) method. This approach combines an enhanced S-transform with adjustable factors for adaptive time–frequency resolution optimization and a multi-scale analysis framework covering three frequency bands. A BP neural network with Gated Recurrent Units captures temporal dependencies, while dynamic sample balancing using K-means clustering addresses sample imbalance and overfitting. Experimental validation on simulation datasets and field data demonstrates that GRU-STF achieves 95.7% accuracy on simulation data and 91.8% on field data, with an average response time of 28 ms, outperforming existing baselines.

Discover ComputingVol. 29(1)
Henan Institute of Technology (CN), Henan Institute of Science and Technology (CN)
Openalex Percentile: Top 6%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.