Pixel-based skin tone estimation on dermoscopy: A dual-rater MST benchmark and feasibility study on lighter skin tones

Public dermoscopy benchmarks such as the International Skin Imaging Collaboration (ISIC) lack skin-tone labels, making it impossible to audit whether clinical AI performs equitably across skin tones. While recent works estimate skin tone automatically from standard clinical photography and selfies, we ask whether this approach is feasible on dermoscopy, the specialized close-up imaging used in these benchmarks. To answer this, we make three contributions. First, we release MST-Derm, a dual-rater Monk Skin Tone (MST) annotation benchmark on 500 ISIC 2018 images. Raters had an explicit unrateable option for images they were unable to label confidently. We find that 60% of images were marked unrateable, yielding a 193-image consensus subset (quadratic-weighted Cohen’s κ = 0.82, indicating excellent inter-annotator agreement). Second, we evaluate three pixel-based MST annotation pipelines: palette matching in perceptual colour space, robust colour statistics, and projection to a 1D colorimetric scalar. All three reach quadratic-weighted κ up to 0.46 against a trivial baseline of 0.00 on a class-balanced subset, which indicates moderate agreement and confirms genuine ordinal signal. On the full evaluation set, where 83% of images are MST 2, a constant “always predict MST 2” baseline achieves higher raw accuracy than every pipeline despite carrying no ordinal skill. Third, we diagnose this performance ceiling. Our results are consistent with dermoscopy’s specialised illumination compressing the colour range on which lighter skin tones differ. ISIC’s dataset skew makes absolute-accuracy metrics uninformative. Because the evaluation set contains no images above MST 5, this validation is restricted to lighter skin tones. We conclude that while pixel-based colour features carry real MST signal on dermoscopy, current performance is insufficient for autonomous annotation. We release the benchmark, annotation protocol, all prediction runs, and analysis code to facilitate development of robust skin-tone estimators, a prerequisite for accurately auditing fairness and mitigating bias in dermatological machine learning.

Authors

Institutions

Publication Details

Journal
PLOS Digital Health
Published
2026-11-25
DOI
https://doi.org/10.1371/journal.pdig.0001854
Primary Topic
Cutaneous Melanoma Detection and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Pixel-based skin tone estimation on dermoscopy: A dual-rater MST benchmark and feasibility study on lighter skin tones

Reza Ghanbarzadeh, Vinh Bui, Amindu Kumarasinghe
4 links
PLOS Digital Health
Cutaneous Melanoma Detection and Management
article

Pixel-based skin tone estimation on dermoscopy: A dual-rater MST benchmark and feasibility study on lighter skin tones

Reza Ghanbarzadeh, Vinh Bui, Amindu Kumarasinghe
article en

Abstract

Public dermoscopy benchmarks such as the International Skin Imaging Collaboration (ISIC) lack skin-tone labels, making it impossible to audit whether clinical AI performs equitably across skin tones. While recent works estimate skin tone automatically from standard clinical photography and selfies, we ask whether this approach is feasible on dermoscopy, the specialized close-up imaging used in these benchmarks. To answer this, we make three contributions. First, we release MST-Derm, a dual-rater Monk Skin Tone (MST) annotation benchmark on 500 ISIC 2018 images. Raters had an explicit unrateable option for images they were unable to label confidently. We find that 60% of images were marked unrateable, yielding a 193-image consensus subset (quadratic-weighted Cohen’s κ = 0.82, indicating excellent inter-annotator agreement). Second, we evaluate three pixel-based MST annotation pipelines: palette matching in perceptual colour space, robust colour statistics, and projection to a 1D colorimetric scalar. All three reach quadratic-weighted κ up to 0.46 against a trivial baseline of 0.00 on a class-balanced subset, which indicates moderate agreement and confirms genuine ordinal signal. On the full evaluation set, where 83% of images are MST 2, a constant “always predict MST 2” baseline achieves higher raw accuracy than every pipeline despite carrying no ordinal skill. Third, we diagnose this performance ceiling. Our results are consistent with dermoscopy’s specialised illumination compressing the colour range on which lighter skin tones differ. ISIC’s dataset skew makes absolute-accuracy metrics uninformative. Because the evaluation set contains no images above MST 5, this validation is restricted to lighter skin tones. We conclude that while pixel-based colour features carry real MST signal on dermoscopy, current performance is insufficient for autonomous annotation. We release the benchmark, annotation protocol, all prediction runs, and analysis code to facilitate development of robust skin-tone estimators, a prerequisite for accurately auditing fairness and mitigating bias in dermatological machine learning.

PLOS Digital HealthVol. 5(11)
Southern Cross University (AU)
Good health and well-being
Cutaneous Melanoma Detection and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon