Modified Cross-Interdental Wiring Technique for Intermaxillary Fixation

The management of maxillofacial fractures relies on fracture reduction, fixation, immobilisation, and restoration of occlusion. Intermaxillary fixation (IMF) is conventionally achieved using arch bars and circumdental wiring; however, these methods are time-consuming and may cause periodontal injury, particularly when only temporary intraoperative stabilisation is required. This study proposes a modified cross-interdental wiring technique for temporary IMF. The method utilises 26-gauge stainless steel wires passed obliquely between maxillary and mandibular molars to achieve buccolingual stabilisation, with twisted ends forming secure rosettes. The technique is indicated in minimally displaced fractures, orthognathic procedures, and paediatric cases where prolonged postoperative IMF is unnecessary. It is contraindicated in severely displaced fractures and edentulous patients. This approach is simple, minimally invasive, requires less operative time, and maintains adequate occlusion. Although challenges exist in compromised dentition and wire removal, the technique offers an efficient alternative to conventional IMF methods for intraoperative stabilisation.

Authors

Publication Details

Journal
Cureus
Published
2026-05-17
DOI
https://doi.org/10.7759/cureus.109037
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modified Cross-Interdental Wiring Technique for Intermaxillary Fixation

Anil Budumuru, Divya Puvvada, Nagasaireddy Konda, Manojkumar Musunuri et al.
Cureus
Facial Trauma and Fracture Management
article

Modified Cross-Interdental Wiring Technique for Intermaxillary Fixation

Anil Budumuru, Divya Puvvada, Nagasaireddy Konda, Manojkumar Musunuri, Rajasatish Prathigudupu
article en

Abstract

The management of maxillofacial fractures relies on fracture reduction, fixation, immobilisation, and restoration of occlusion. Intermaxillary fixation (IMF) is conventionally achieved using arch bars and circumdental wiring; however, these methods are time-consuming and may cause periodontal injury, particularly when only temporary intraoperative stabilisation is required. This study proposes a modified cross-interdental wiring technique for temporary IMF. The method utilises 26-gauge stainless steel wires passed obliquely between maxillary and mandibular molars to achieve buccolingual stabilisation, with twisted ends forming secure rosettes. The technique is indicated in minimally displaced fractures, orthognathic procedures, and paediatric cases where prolonged postoperative IMF is unnecessary. It is contraindicated in severely displaced fractures and edentulous patients. This approach is simple, minimally invasive, requires less operative time, and maintains adequate occlusion. Although challenges exist in compromised dentition and wire removal, the technique offers an efficient alternative to conventional IMF methods for intraoperative stabilisation.

Cureus
Openalex Percentile: Top 6%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.