Single‐Shot <scp>2D</scp> Radial Echo Planar Imaging for Functional <scp>MRI</scp>

ABSTRACT Purpose To develop a novel single‐shot radial echo planar imaging (ss‐rEPI) technique for rapid, distortion‐free brain imaging in functional MRI experiments. Methods Radial multi‐gradient echo (radial mGRE) data were acquired on a 3T clinical scanner using a 2D ss‐rEPI readout with small golden‐angle rotations between echoes. Images were reconstructed using an iterative conjugate‐gradient method incorporating coil sensitivities, B 0 field inhomogeneities, transverse relaxation, and field‐drift correction to account for signal inconsistencies in the extended mGRE readout. Additional k ‐space‐weighted image contrast (KWIC) filtering prior to reconstruction helped reduce model mismatches at low spatial frequencies. Single‐shot rEPI image quality, contrast, and distortion were assessed against multi‐shot radial mGRE reference data. Retrospective adjustment of the KWIC filter and target TE in the reconstruction allowed the generation of multiple T 2 *weighted and phase contrast images from a single ss‐rEPI scan, enabling quantitative T 2 * mapping and QSM. Visual BOLD fMRI experiments were conducted and evaluated against Cartesian EPI measurements. Results Twenty‐four 3 mm thick slices of distortion‐free, multi‐contrast brain images were obtained at 2 × 2 and 1.5 mm 2 (ramp‐sampled) in‐plane resolution with an acquisition time of under 1.7 s. In multi‐session fMRI experiments on two subjects, ss‐rEPI demonstrated BOLD activation in the visual cortex comparable to standard EPI while also enabling functional T 2 * measurements. Conclusion Single‐shot rEPI enables rapid, distortion‐free 2D multi‐contrast brain imaging, offering a promising alternative to Cartesian EPI. Accurate ∆ B 0 modeling is critical for ss‐rEPI performance. Advanced reconstruction techniques and self‐calibration methods could further enhance its speed, performance, and applicability across diverse MRI techniques.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-05-17
DOI
https://doi.org/10.1002/mrm.70433
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single‐Shot 2D Radial Echo Planar Imaging for Functional MRI

Kai Tobias Block, Zidan Yu, Christoph A. Rettenmeier, V. Andrew Stenger et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

Single‐Shot 2D Radial Echo Planar Imaging for Functional MRI

Kai Tobias Block, Zidan Yu, Christoph A. Rettenmeier, V. Andrew Stenger, Krystalyn Edwards‐Calma
article en

Abstract

ABSTRACT Purpose To develop a novel single‐shot radial echo planar imaging (ss‐rEPI) technique for rapid, distortion‐free brain imaging in functional MRI experiments. Methods Radial multi‐gradient echo (radial mGRE) data were acquired on a 3T clinical scanner using a 2D ss‐rEPI readout with small golden‐angle rotations between echoes. Images were reconstructed using an iterative conjugate‐gradient method incorporating coil sensitivities, B 0 field inhomogeneities, transverse relaxation, and field‐drift correction to account for signal inconsistencies in the extended mGRE readout. Additional k ‐space‐weighted image contrast (KWIC) filtering prior to reconstruction helped reduce model mismatches at low spatial frequencies. Single‐shot rEPI image quality, contrast, and distortion were assessed against multi‐shot radial mGRE reference data. Retrospective adjustment of the KWIC filter and target TE in the reconstruction allowed the generation of multiple T 2 *weighted and phase contrast images from a single ss‐rEPI scan, enabling quantitative T 2 * mapping and QSM. Visual BOLD fMRI experiments were conducted and evaluated against Cartesian EPI measurements. Results Twenty‐four 3 mm thick slices of distortion‐free, multi‐contrast brain images were obtained at 2 × 2 and 1.5 mm 2 (ramp‐sampled) in‐plane resolution with an acquisition time of under 1.7 s. In multi‐session fMRI experiments on two subjects, ss‐rEPI demonstrated BOLD activation in the visual cortex comparable to standard EPI while also enabling functional T 2 * measurements. Conclusion Single‐shot rEPI enables rapid, distortion‐free 2D multi‐contrast brain imaging, offering a promising alternative to Cartesian EPI. Accurate ∆ B 0 modeling is critical for ss‐rEPI performance. Advanced reconstruction techniques and self‐calibration methods could further enhance its speed, performance, and applicability across diverse MRI techniques.

Magnetic Resonance in Medicine
University of Hawaiʻi at Mānoa (US), New York University (US)
National Institutes of Health
Openalex Percentile: Top 6%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.