Toward Free‐Breathing Renal <scp>CEST MRI</scp> : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach

ABSTRACT Purpose Endogenous renal chemical exchange saturation transfer (CEST) imaging enables contrast‐agent‐free assessment of renal metabolism but is highly sensitive to respiratory motion. Existing approaches, such as timed breathing, require high patient compliance or preclinical mechanical ventilation, limiting clinical translation. We evaluated a free‐breathing prospective respiratory triggering method that allows continuous saturation during active breathing while adaptively aligning image acquisition with the expiratory phase. Methods Prospective triggering was based on a modified real‐time respiratory signal, with a temporal shift continuously updated according to the current respiratory rate. Simulations assessed its performance across saturation durations of 1–6 s, respiratory rates representative of preclinical and clinical settings (f = 8–90 bpm), and varying respiratory frequency (CV = 0%–25%). Results were compared to conventional real‐time triggering. For in vivo validation, prospective triggering was implemented on a preclinical 7 T MRI system using a Raspberry Pi‐based hardware and software. Six mice underwent CEST imaging with saturation durations of 1, 3, and 5 s using both real‐time and prospective triggering, and the Mean Squared Error of Lorentzian fit was used to compare the two approaches. Results The real‐time trigger error shows a periodic dependence on respiratory frequency, which diminishes with increasing variability, whereas the prospective trigger reduces this periodicity. In vivo, prospective triggering significantly ( p &lt; 0.05) reduced motion‐induced scattering in the Z‐spectrum for saturation times up to 3 s and enabled the detection of distinct metabolic contrasts across renal compartments. Conclusion Prospective triggering effectively reduces motion artifacts in preclinical renal CEST imaging.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-05-17
DOI
https://doi.org/10.1002/mrm.70435
Primary Topic
Lanthanide and Transition Metal Complexes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward Free‐Breathing Renal CEST MRI : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach

Karl Ludger Radke, H Wittsack, Julia Stabinska, Маргарита Ткаченко et al.
Magnetic Resonance in Medicine
Lanthanide and Transition Metal Complexes
article

Toward Free‐Breathing Renal CEST MRI : Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach

Karl Ludger Radke, H Wittsack, Julia Stabinska, Маргарита Ткаченко, Luděk Šefc, Pavla Francová, Anja Müller‐Lutz, Vı́t Herynek, Patrik Jan Gallinnis, Martin Dusa, A Ljimani, Gerald Antoch, Ruslan Garipov
article en

Abstract

ABSTRACT Purpose Endogenous renal chemical exchange saturation transfer (CEST) imaging enables contrast‐agent‐free assessment of renal metabolism but is highly sensitive to respiratory motion. Existing approaches, such as timed breathing, require high patient compliance or preclinical mechanical ventilation, limiting clinical translation. We evaluated a free‐breathing prospective respiratory triggering method that allows continuous saturation during active breathing while adaptively aligning image acquisition with the expiratory phase. Methods Prospective triggering was based on a modified real‐time respiratory signal, with a temporal shift continuously updated according to the current respiratory rate. Simulations assessed its performance across saturation durations of 1–6 s, respiratory rates representative of preclinical and clinical settings (f = 8–90 bpm), and varying respiratory frequency (CV = 0%–25%). Results were compared to conventional real‐time triggering. For in vivo validation, prospective triggering was implemented on a preclinical 7 T MRI system using a Raspberry Pi‐based hardware and software. Six mice underwent CEST imaging with saturation durations of 1, 3, and 5 s using both real‐time and prospective triggering, and the Mean Squared Error of Lorentzian fit was used to compare the two approaches. Results The real‐time trigger error shows a periodic dependence on respiratory frequency, which diminishes with increasing variability, whereas the prospective trigger reduces this periodicity. In vivo, prospective triggering significantly ( p &lt; 0.05) reduced motion‐induced scattering in the Z‐spectrum for saturation times up to 3 s and enabled the detection of distinct metabolic contrasts across renal compartments. Conclusion Prospective triggering effectively reduces motion artifacts in preclinical renal CEST imaging.

Magnetic Resonance in Medicine
Kennedy Krieger Institute (US), Johns Hopkins University (US), Charles University (CZ), Johns Hopkins Medicine (US), Düsseldorf University Hospital (DE), Materials Solutions (United Kingdom) (GB), Heinrich Heine University Düsseldorf (DE)
Univerzita Karlova v Praze, Jürgen Manchot Stiftung, Deutsche Forschungsgemeinschaft, Ministerstvo Školství, Mládeže a Tělovýchovy, European Regional Development Fund
Openalex Percentile: Top 12%
Lanthanide and Transition Metal Complexes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.