Analytical evaluation of cable corrosion effects on the residual prestressing coactive state in post-tensioned concrete elements

The paper provides an original analytical evaluation of the effects of cable corrosion on the prestressing coactive state in post-tensioned concrete elements (namely, beams and stays in prestressed bridges), in which steel cables are made adherent through subsequent cast-in-situ grouting. The corrosion is assumed to be homogeneously distributed over a finite portion of the sheathing duct characterized by lack of mortar injection, and modeled as a uniform cross-section loss. The study analytically demonstrates that the reduction of the cross-sectional area of the prestressing steel cables due to corrosion generates both (I) a loss of the prestressing force and (II) a stress redistribution within the residual cross-sectional area of the cables, which are limited to the zone lacking grouting. Ready-to-use closed-form mathematical expressions for these two effects are derived allowing direct quantification of the corrosion-induced variation of the prestressing state, for the two cases of concentric and eccentric tendons, and validated against experimental results available in the scientific literature. A numerical application to three typical existing bridge elements is also provided. The fundamental result is that the loss of the prestressing force is approximately equal to the cross-section loss, while the stress redistribution is comparatively small, providing a cable stress increase below 5% for bridge decks and below 25% for stays, even for highly corroded cables. • Original analytical model assesses corrosion effects in post-tensioned elements. • Corrosion is modeled as uniform steel loss in ungrouted duct sections. • Closed-form solutions quantify prestressing force loss and stress redistribution. • Models developed for both concentric and eccentric tendon configurations. • Prestress loss roughly equal to cross-section loss; dominates over stress increase.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2026-05-17
DOI
https://doi.org/10.1016/j.engstruct.2026.122997
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical evaluation of cable corrosion effects on the residual prestressing coactive state in post-tensioned concrete elements

Stefano Silvestri, Matteo Marra, Emma Ghini, Giada Gasparini
Engineering Structures
Concrete Corrosion and Durability
article

Analytical evaluation of cable corrosion effects on the residual prestressing coactive state in post-tensioned concrete elements

Stefano Silvestri, Matteo Marra, Emma Ghini, Giada Gasparini
article en

Abstract

The paper provides an original analytical evaluation of the effects of cable corrosion on the prestressing coactive state in post-tensioned concrete elements (namely, beams and stays in prestressed bridges), in which steel cables are made adherent through subsequent cast-in-situ grouting. The corrosion is assumed to be homogeneously distributed over a finite portion of the sheathing duct characterized by lack of mortar injection, and modeled as a uniform cross-section loss. The study analytically demonstrates that the reduction of the cross-sectional area of the prestressing steel cables due to corrosion generates both (I) a loss of the prestressing force and (II) a stress redistribution within the residual cross-sectional area of the cables, which are limited to the zone lacking grouting. Ready-to-use closed-form mathematical expressions for these two effects are derived allowing direct quantification of the corrosion-induced variation of the prestressing state, for the two cases of concentric and eccentric tendons, and validated against experimental results available in the scientific literature. A numerical application to three typical existing bridge elements is also provided. The fundamental result is that the loss of the prestressing force is approximately equal to the cross-section loss, while the stress redistribution is comparatively small, providing a cable stress increase below 5% for bridge decks and below 25% for stays, even for highly corroded cables. • Original analytical model assesses corrosion effects in post-tensioned elements. • Corrosion is modeled as uniform steel loss in ungrouted duct sections. • Closed-form solutions quantify prestressing force loss and stress redistribution. • Models developed for both concentric and eccentric tendon configurations. • Prestress loss roughly equal to cross-section loss; dominates over stress increase.

Engineering StructuresVol. 362
University of Bologna (IT)
Sustainable cities and communities
Openalex Percentile: Top 9%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.