Cut point validation vs. real-world performance: the ultra-low cut point dilemma

Cut point determination is a critical component in the development and validation of antidrug antibody (ADA) assays, directly influencing the assessment of immunogenic responses. Removal of analytical and biological outliers from employing Tukey's outlier test may lead to reduced variability and consequently low or ultra-low cut points (ULCPs, defined here as signal-to-noise ratios ≤1.10). Such ULCPs raise concerns about assay reliability and the potential for elevated false-positive rates. To evaluate this, we analyzed ADA studies from two contract research organizations employing ULCPs. Given the heightened assay sensitivity from modern platforms and reagents, our findings indicate that ULCPs do not inherently compromise ADA assay performance or reliability. These results support the continued use of ULCPs when appropriately validated and statistically justified.

Authors

Institutions

Publication Details

Journal
Bioanalysis
Published
2026-05-16
DOI
https://doi.org/10.1080/17576180.2026.2672454
Primary Topic
Parallel Computing and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cut point validation vs. real-world performance: the ultra-low cut point dilemma

Liam Heins, Cansu Dernek, Stephanie Pasas-Farmer, Robert Kernstock et al.
Bioanalysis
Parallel Computing and Optimization Techniques
article

Cut point validation vs. real-world performance: the ultra-low cut point dilemma

Liam Heins, Cansu Dernek, Stephanie Pasas-Farmer, Robert Kernstock, Allie Renfro, Chong Gu, Lindsay Denhoff
article en

Abstract

Cut point determination is a critical component in the development and validation of antidrug antibody (ADA) assays, directly influencing the assessment of immunogenic responses. Removal of analytical and biological outliers from employing Tukey's outlier test may lead to reduced variability and consequently low or ultra-low cut points (ULCPs, defined here as signal-to-noise ratios ≤1.10). Such ULCPs raise concerns about assay reliability and the potential for elevated false-positive rates. To evaluate this, we analyzed ADA studies from two contract research organizations employing ULCPs. Given the heightened assay sensitivity from modern platforms and reagents, our findings indicate that ULCPs do not inherently compromise ADA assay performance or reliability. These results support the continued use of ULCPs when appropriately validated and statistically justified.

Bioanalysis
Astellas Pharma (Japan) (JP), 490 BioTech (United States) (US), Ta Solutions (China) (CN), Imperial Consultants (GB)
Reduced inequalities
Openalex Percentile: Top 2%
Parallel Computing and Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.