Coronary stenosis assessment: AI-based CT quantification, visual analysis of invasive angiography, and quantitative coronary angiography
Abstract Objective To evaluate the diagnostic performance for coronary stenosis of artificial intelligence (AI)-based CT quantification, manual CT quantification, and visual invasive coronary angiography (ICA) assessment against quantitative coronary angiography (QCA). Materials and methods This retrospective study included patients who underwent both coronary CT angiography (CCTA) and ICA within 1 month. Diameter stenosis (DS) was quantified on CCTA images both automatically by a deep-learning model and manually by radiologists, and was assessed visually on ICA. Diagnostic performance for detecting obstructive stenosis (DS ≥ 50% and ≥ 70%) was assessed against QCA using receiver operating characteristic (ROC) curve analysis on per-patient, per-vessel, and per-segment levels. Agreement with QCA was evaluated using Bland-Altman analysis. Results A total of 368 patients were included. AI-based CT quantification demonstrated high diagnostic accuracy. For DS ≥ 50%, area under the curves (AUCs) were 0.93 (per-patient), 0.94 (per-vessel), and 0.96 (per-segment). For DS ≥ 70%, AUCs were 0.85, 0.89, and 0.90, respectively. AI-based CT quantification significantly outperformed manual CT and visual ICA assessments at most levels in terms of AUC (all p < 0.05), except vs manual quantification by a senior radiologist at the segment level for ≥ 70% stenosis ( p = 0.060). Bland-Altman analysis showed superior agreement between AI-based CT quantification of DS and QCA (mean differences: 1.5% per-patient, −0.7% per-vessel, −1.2% per-segment) compared with manual CT quantification and visual assessment of ICA. Conclusions AI-based CT quantification demonstrated high diagnostic performance for obstructive stenosis with good agreement against QCA, outperforming manual CT quantification and visual assessment of ICA in most scenarios, with the exception of segment-level assessment of ≥ 70% DS compared with manual quantification by senior radiologists. Critical relevance statement AI-aided CT quantification outperforms both manual CT quantification and visual ICA analysis in diagnosing obstructive stenosis using QCA as the reference standard, providing an objective tool to reduce diagnostic uncertainty and guide subsequent patient management. Key Points Manual coronary stenosis quantification is subject to significant inter-observer variability. AI-based CT quantification outperforms both manual CT quantification and visual ICA analysis. Discordance between AI results and the angiographer’s visual estimation should prompt a physiological evaluation. Graphical Abstract
Authors
- L XU
- Jiajun Yuan
- Mingyuan Yuan (ORCID: https://orcid.org/0000-0002-6950-2864)
- Li Yu
- Dai X (ORCID: https://orcid.org/0000-0002-9941-1357)
- Chao Zheng
- Ting Liu
- Jiayin Zhang (ORCID: https://orcid.org/0000-0001-7383-7571)
- Yarong Yu
Institutions
- Shanghai Jiao Tong University (CN)
- Capital Medical University (CN)
- Beijing Anzhen Hospital (CN)
- Shanghai First People's Hospital (CN)
- Shanghai University of Medicine and Health Sciences (CN)
- First Hospital of China Medical University (CN)
- China Medical University (CN)
Publication Details
- Journal
- Insights into Imaging
- Published
- 2026-05-16
- DOI
- https://doi.org/10.1186/s13244-026-02308-2
- Primary Topic
- Cardiac Imaging and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China
- Shanghai Municipal Education Commission
- Science and Technology Commission of Shanghai Municipality
- National Key Research and Development Program of China