Effect of moderate Stenosis on the upstream and downstream flow patterns in the Internal Carotid artery- An Invitro Investigation

Abstract Narrowing of the internal carotid artery (ICA), known as stenosis, can significantly alter normal blood flow and increase the likelihood of cerebrovascular complications such as ischemic stroke. This study presents an in vitro investigation of flow dynamics within a stenosed ICA with an aneurysm at the carotid ophthalmic junction. A blood-mimicking fluid was circulated through the model, allowing for flow behavior similar to physiological conditions. Flow visualization was achieved using Particle Streak Velocimetry (PSV), a non-invasive optical measurement technique capable of capturing the detailed velocity fields. The axial velocity revealed an interesting phenomenon: the velocity profile became smoother and tended towards a more parabolic shape compared to the non-stenotic case, where the peak typically shifts toward the inner curvature region. However, this asymmetry became less pronounced within the stenotic section. The presence of stenosis introduces an equivalent opposing curvature, which effectively neutralizes the asymmetric flow distribution. Furthermore, the transverse velocity component (v) was plotted along the axial direction (x) to assess secondary flow behavior. The resulting v versus x plot exhibited clear indications of flow disturbances and recirculation zones downstream of the constriction. These findings demonstrate how stenosis modifies the flow structure within the artery, potentially contributing to adverse clinical outcomes. The experimental approach using a blood-mimicking fluid and PSV enables a detailed understanding of hemodynamic behavior in stenosed arteries. Such insights are valuable for advancing diagnostic methods and improving treatment planning in vascular diseases.

Authors

Institutions

Publication Details

Journal
Journal of Engineering and Science in Medical Diagnostics and Therapy
Published
2026-05-16
DOI
https://doi.org/10.1115/1.4071950
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of moderate Stenosis on the upstream and downstream flow patterns in the Internal Carotid artery- An Invitro Investigation

K. C. Tripathy, Ajay Bhandari, G Kumar
Journal of Engineering and Science in Medical Diagnostics and Therapy
Coronary Interventions and Diagnostics
article

Effect of moderate Stenosis on the upstream and downstream flow patterns in the Internal Carotid artery- An Invitro Investigation

K. C. Tripathy, Ajay Bhandari, G Kumar
article en

Abstract

Abstract Narrowing of the internal carotid artery (ICA), known as stenosis, can significantly alter normal blood flow and increase the likelihood of cerebrovascular complications such as ischemic stroke. This study presents an in vitro investigation of flow dynamics within a stenosed ICA with an aneurysm at the carotid ophthalmic junction. A blood-mimicking fluid was circulated through the model, allowing for flow behavior similar to physiological conditions. Flow visualization was achieved using Particle Streak Velocimetry (PSV), a non-invasive optical measurement technique capable of capturing the detailed velocity fields. The axial velocity revealed an interesting phenomenon: the velocity profile became smoother and tended towards a more parabolic shape compared to the non-stenotic case, where the peak typically shifts toward the inner curvature region. However, this asymmetry became less pronounced within the stenotic section. The presence of stenosis introduces an equivalent opposing curvature, which effectively neutralizes the asymmetric flow distribution. Furthermore, the transverse velocity component (v) was plotted along the axial direction (x) to assess secondary flow behavior. The resulting v versus x plot exhibited clear indications of flow disturbances and recirculation zones downstream of the constriction. These findings demonstrate how stenosis modifies the flow structure within the artery, potentially contributing to adverse clinical outcomes. The experimental approach using a blood-mimicking fluid and PSV enables a detailed understanding of hemodynamic behavior in stenosed arteries. Such insights are valuable for advancing diagnostic methods and improving treatment planning in vascular diseases.

Journal of Engineering and Science in Medical Diagnostics and Therapy
Indian Institute of Technology Dhanbad (IN)
Good health and well-being
Openalex Percentile: Top 4%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.