Spectral Induced Polarization Laboratory Measurements Combining Two and Four-Electrode Measurement Configurations

Summary Spectral Induced Polarization (SIP) is a geophysical technique which measures the frequency dependent electrical properties of geologic materials which can, in turn, be linked to underlying petrophysical parameters. Four-electrode SIP measurements exhibit errors above 100 Hz related to parasitic capacitive coupling (PCC) inside of the instrumentation and to the impedance of the potential electrodes. These errors can easily mask the true sample response. Existing techniques to correct SIP data infected with these errors can be complex and prone to operational error. Here we present a simple procedure that utilizes joint two- and four-electrode measurements using the same sample holder to validate high frequency SIP data. We tested the practicality of this approach by performing a series of two electrode SIP measurements on a known NaCl solution using conventional coiled current electrodes composed of different metals. We compared this procedure with both theoretical values and against a four-electrode correction procedure (referred to as the Wang correction), which utilizes four impedance measurements to directly calculate high frequency phase errors in instruments with differential amplifiers. We found that two electrode measurements conducted with coiled Ag-AgCl electrodes performed well for resistive samples and for highly polarizable samples above 100 Hz, and for conductive samples above 1 kHz. The use of joint two- and four-electrode measurements on the same sample holder is simpler than existing correction techniques and presents a straightforward alternative to the validation of high-frequency four-electrode data.

Authors

Institutions

Publication Details

Journal
Geophysical Journal International
Published
2026-05-14
DOI
https://doi.org/10.1093/gji/ggag177
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectral Induced Polarization Laboratory Measurements Combining Two and Four-Electrode Measurement Configurations

Lee Slater, Alejandro Garcia
Geophysical Journal International
Geophysical and Geoelectrical Methods
article

Spectral Induced Polarization Laboratory Measurements Combining Two and Four-Electrode Measurement Configurations

Lee Slater, Alejandro Garcia
article en

Abstract

Summary Spectral Induced Polarization (SIP) is a geophysical technique which measures the frequency dependent electrical properties of geologic materials which can, in turn, be linked to underlying petrophysical parameters. Four-electrode SIP measurements exhibit errors above 100 Hz related to parasitic capacitive coupling (PCC) inside of the instrumentation and to the impedance of the potential electrodes. These errors can easily mask the true sample response. Existing techniques to correct SIP data infected with these errors can be complex and prone to operational error. Here we present a simple procedure that utilizes joint two- and four-electrode measurements using the same sample holder to validate high frequency SIP data. We tested the practicality of this approach by performing a series of two electrode SIP measurements on a known NaCl solution using conventional coiled current electrodes composed of different metals. We compared this procedure with both theoretical values and against a four-electrode correction procedure (referred to as the Wang correction), which utilizes four impedance measurements to directly calculate high frequency phase errors in instruments with differential amplifiers. We found that two electrode measurements conducted with coiled Ag-AgCl electrodes performed well for resistive samples and for highly polarizable samples above 100 Hz, and for conductive samples above 1 kHz. The use of joint two- and four-electrode measurements on the same sample holder is simpler than existing correction techniques and presents a straightforward alternative to the validation of high-frequency four-electrode data.

Geophysical Journal International
Rutgers, The State University of New Jersey (US), Pacific Northwest National Laboratory (US), Cold Regions Research and Engineering Laboratory (US), University Hospital, Newark (US)
Openalex Percentile: Top 4%
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.