CHROMATOGRAPHIC AND COMPUTATIONAL APPROACHES TO THE PHARMACOKINETIC PROFILE OF PIROXICAM AND ITS SENSITIVE ASSAY IN RABBIT PLASMA

Objective: A simple, rapid, sensitive, and cost-effective high-performance liquid chromatographic (HPLC) method was developed for the pharmacokinetic study and determination of Piroxicam.Material and Method: The chromatographic separation was performed with a Agilent ZORBAX reversed-phase C18 column (250 mm × 4,6 mm ID × 5 μm). Mobile phase composition was 0.04 M KH2PO4: acetonitrile:methanol (50:40:10) at pH 3.8. The flow rate was adjusted as 0.9 mL/min.Result and Discussion: An isocratic method was used for the analysis. The UV detector was set at 360 nm, and a retention time of 7 minutes was obtained for piroxicam. The method showed linear performance over the concentration range of 0.1–4 mg/l.

Authors

Institutions

Publication Details

Journal
Ankara Universitesi Eczacilik Fakultesi Dergisi
Published
2026-05-14
DOI
https://doi.org/10.33483/jfpau.1766558
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CHROMATOGRAPHIC AND COMPUTATIONAL APPROACHES TO THE PHARMACOKINETIC PROFILE OF PIROXICAM AND ITS SENSITIVE ASSAY IN RABBIT PLASMA

Özgür Eşi̇m, Ayhan Savaşer, Yalçın Özkan, Berk Alp Göksel et al.
Ankara Universitesi Eczacilik Fakultesi Dergisi
Analytical Methods in Pharmaceuticals
article

CHROMATOGRAPHIC AND COMPUTATIONAL APPROACHES TO THE PHARMACOKINETIC PROFILE OF PIROXICAM AND ITS SENSITIVE ASSAY IN RABBIT PLASMA

Özgür Eşi̇m, Ayhan Savaşer, Yalçın Özkan, Berk Alp Göksel, Engin Koçak, Nurgül K. Bakırhan, Okan Ali Aksoy, Esra Merve Zanbak Çotaoğlu, Tugba Taskın Tok, Sibel A. Özkan
article en

Abstract

Objective: A simple, rapid, sensitive, and cost-effective high-performance liquid chromatographic (HPLC) method was developed for the pharmacokinetic study and determination of Piroxicam.Material and Method: The chromatographic separation was performed with a Agilent ZORBAX reversed-phase C18 column (250 mm × 4,6 mm ID × 5 μm). Mobile phase composition was 0.04 M KH2PO4: acetonitrile:methanol (50:40:10) at pH 3.8. The flow rate was adjusted as 0.9 mL/min.Result and Discussion: An isocratic method was used for the analysis. The UV detector was set at 360 nm, and a retention time of 7 minutes was obtained for piroxicam. The method showed linear performance over the concentration range of 0.1–4 mg/l.

Ankara Universitesi Eczacilik Fakultesi Dergisi(Advanced Online Publication)
Ankara University (TR), Akdeniz University (TR), Sağlık Bilimleri Üniversitesi (TR), University of Health Sciences (SO)
Openalex Percentile: Top 6%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.