Is the interventional glaucoma paradigm reflected in real-world practice? Insights from iStent combined with cataract surgery (2010–2022)

PurposeTo analyze trends in the clinical use of the iStent device, characterize the evolving baseline profile of treated patients, and assess surgical outcomes over time.MethodsThis retrospective longitudinal study included 145 eyes undergoing iStent implantation between 2010 and 2022. Data included intraocular pressure (IOP), medications, and functional and structural parameters. Surgical success was defined using three criteria: (1) IOP <21 mmHg with medication reduction, (2) IOP <18 mmHg with medication reduction, and (3) IOP <21 mmHg with a ≥ 20% reduction from baseline.ResultsiStent use increased from 3.4% to 9.4% of glaucoma surgeries (p = 0.0125). Combined phaco-iStent surgery was performed in 95.9% of eyes. At 12-month, mean IOP decreased from 19.2 ± 4.5 mmHg to 16.4 ± 2.5 mmHg, with medications reduced from 1.9 ± 0.8 to 0.6 ± 0.8. Surgical success was achieved in 81.0% of eyes according to Criterion 1, 64.9% according to Criterion 2, and 49.6% according to Criterion 3. Over time, surgical success progressively improved, reaching 89.8% (Criterion 1), 78.0% (Criterion 2), and 57.6% (Criterion 3) between 2020 and 2022, while surgeries were increasingly performed in patients with lower baseline IOP and less advanced visual field loss.ConclusionOver the past decade, the iStent has become increasingly integrated into routine clinical practice. Compared with its early use, indications have expanded toward earlier stages of glaucoma, accompanied by improved surgical success and reduced medication burden. These results support the idea that the surgical treatment of glaucoma is gradually evolving towards earlier and more individualized surgical intervention.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2026-05-14
DOI
https://doi.org/10.1177/11206721261452042
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is the interventional glaucoma paradigm reflected in real-world practice? Insights from iStent combined with cataract surgery (2010–2022)

Javier García-Bardera, Mireia García-Bermúdez, Laura Morales-Fernández, José María Martínez-de-la-Casa et al.
European Journal of Ophthalmology
Glaucoma and retinal disorders
article

Is the interventional glaucoma paradigm reflected in real-world practice? Insights from iStent combined with cataract surgery (2010–2022)

Javier García-Bardera, Mireia García-Bermúdez, Laura Morales-Fernández, José María Martínez-de-la-Casa, Julian Garcia-Feijoo, Marta Pons-María
article en

Abstract

PurposeTo analyze trends in the clinical use of the iStent device, characterize the evolving baseline profile of treated patients, and assess surgical outcomes over time.MethodsThis retrospective longitudinal study included 145 eyes undergoing iStent implantation between 2010 and 2022. Data included intraocular pressure (IOP), medications, and functional and structural parameters. Surgical success was defined using three criteria: (1) IOP <21 mmHg with medication reduction, (2) IOP <18 mmHg with medication reduction, and (3) IOP <21 mmHg with a ≥ 20% reduction from baseline.ResultsiStent use increased from 3.4% to 9.4% of glaucoma surgeries (p = 0.0125). Combined phaco-iStent surgery was performed in 95.9% of eyes. At 12-month, mean IOP decreased from 19.2 ± 4.5 mmHg to 16.4 ± 2.5 mmHg, with medications reduced from 1.9 ± 0.8 to 0.6 ± 0.8. Surgical success was achieved in 81.0% of eyes according to Criterion 1, 64.9% according to Criterion 2, and 49.6% according to Criterion 3. Over time, surgical success progressively improved, reaching 89.8% (Criterion 1), 78.0% (Criterion 2), and 57.6% (Criterion 3) between 2020 and 2022, while surgeries were increasingly performed in patients with lower baseline IOP and less advanced visual field loss.ConclusionOver the past decade, the iStent has become increasingly integrated into routine clinical practice. Compared with its early use, indications have expanded toward earlier stages of glaucoma, accompanied by improved surgical success and reduced medication burden. These results support the idea that the surgical treatment of glaucoma is gradually evolving towards earlier and more individualized surgical intervention.

European Journal of Ophthalmology
Universidad Complutense de Madrid (ES), Hospital Clínico San Carlos (ES), Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (ES), Hospital Universitario Quirónsalud Madrid (ES)
Openalex Percentile: Top 3%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.