Prestress Loss and Bi-Directional Prestress Effect of a Large-Span U-Shaped Aqueduct: Field Test and Numerical Analysis

Prestress loss and bi-directional prestress effects are critical design parameters that determine the bearing capacity of large-span U-shaped aqueducts. Based on a 42 m span simply supported U-shaped aqueduct, the pipeline friction coefficients were tested through least-squares fitting and validated against a finite element analysis model. The results revealed pipeline friction induced 4.82–5.08% longitudinal and 35.84–39.23% circumferential prestress loss, with 12-month post-tensioning monitoring showing 9.84% (longitudinal) and 3.15% (circumferential) long-term loss. Maximum concrete compressive stresses reached 5.83 MPa (inner wall) and 7.14 MPa (outer wall) under empty groove conditions. Six prestress tensioning sequences were numerically compared to identify the optimal “both ends to center” circumferential tensioning scheme. The prestressed tendon layout was optimized by increasing circumferential tendon spacing from 40 cm to 60 cm while maintaining global compression. This research provides a systematic framework for prestress optimization in curved concrete structures.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-05-14
DOI
https://doi.org/10.3390/eng7050239
Primary Topic
Concrete Properties and Behavior
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prestress Loss and Bi-Directional Prestress Effect of a Large-Span U-Shaped Aqueduct: Field Test and Numerical Analysis

Xi Zhang, LIU Pingan, WANG Tiehu, Yupeng Ou
Eng—Advances in Engineering
Concrete Properties and Behavior
article

Prestress Loss and Bi-Directional Prestress Effect of a Large-Span U-Shaped Aqueduct: Field Test and Numerical Analysis

Xi Zhang, LIU Pingan, WANG Tiehu, Yupeng Ou
article en

Abstract

Prestress loss and bi-directional prestress effects are critical design parameters that determine the bearing capacity of large-span U-shaped aqueducts. Based on a 42 m span simply supported U-shaped aqueduct, the pipeline friction coefficients were tested through least-squares fitting and validated against a finite element analysis model. The results revealed pipeline friction induced 4.82–5.08% longitudinal and 35.84–39.23% circumferential prestress loss, with 12-month post-tensioning monitoring showing 9.84% (longitudinal) and 3.15% (circumferential) long-term loss. Maximum concrete compressive stresses reached 5.83 MPa (inner wall) and 7.14 MPa (outer wall) under empty groove conditions. Six prestress tensioning sequences were numerically compared to identify the optimal “both ends to center” circumferential tensioning scheme. The prestressed tendon layout was optimized by increasing circumferential tendon spacing from 40 cm to 60 cm while maintaining global compression. This research provides a systematic framework for prestress optimization in curved concrete structures.

Eng—Advances in EngineeringVol. 7(5)
PowerChina (China) (CN), Southwest Jiaotong University (CN)
Sustainable cities and communities
Openalex Percentile: Top 7%
Concrete Properties and Behavior
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.