The Impact of High Voltage Power Transformer Base Design on Bushing Seismic Amplification

ABSTRACT High voltage power transformer bushings (230 kV and above) are a known seismic vulnerability, often failing during significant earthquakes and causing potential disruption to the power supply. This occurs most commonly when the dynamic resonance between the transformer tank and the mounted bushing causes excessive amplification of the seismic demands to the bushing, leading to failure. This study evaluates multiple existing transformer designs that include stiffness discontinuities near the foundation, and the impact on the system dynamic response that results from mitigating these discontinuities with simple and potentially retrofittable blocking below the tank corners. The results of the study show that modifying the transformer bases to have an increased stiffness between the foundation and transformer tank causes a reduction in seismic high voltage bushing stress—with an average reduction of 37%.

Authors

Institutions

Publication Details

Journal
Earthquake Engineering & Structural Dynamics
Published
2026-05-12
DOI
https://doi.org/10.1002/eqe.70177
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of High Voltage Power Transformer Base Design on Bushing Seismic Amplification

Chandrakanth Bolisetti, Bjorn Vaagensmith, Jon Bender, Aisha McKee
Earthquake Engineering & Structural Dynamics
Seismic Performance and Analysis
article

The Impact of High Voltage Power Transformer Base Design on Bushing Seismic Amplification

Chandrakanth Bolisetti, Bjorn Vaagensmith, Jon Bender, Aisha McKee
article en

Abstract

ABSTRACT High voltage power transformer bushings (230 kV and above) are a known seismic vulnerability, often failing during significant earthquakes and causing potential disruption to the power supply. This occurs most commonly when the dynamic resonance between the transformer tank and the mounted bushing causes excessive amplification of the seismic demands to the bushing, leading to failure. This study evaluates multiple existing transformer designs that include stiffness discontinuities near the foundation, and the impact on the system dynamic response that results from mitigating these discontinuities with simple and potentially retrofittable blocking below the tank corners. The results of the study show that modifying the transformer bases to have an increased stiffness between the foundation and transformer tank causes a reduction in seismic high voltage bushing stress—with an average reduction of 37%.

Earthquake Engineering & Structural Dynamics
Idaho National Laboratory (US), Family Medicine Residency of Idaho (US)
Sustainable cities and communities
Openalex Percentile: Top 7%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Impact of High Voltage Power Transformer Base Design on Bushing Seismic Amplification — Chandrakanth Bolisetti, Bjorn Vaagensmith, et al. · Earthquake Engineering & Structural Dynamics (2026) | TGRS Research Map | TGRS