Which is the best laser for ureteroscopy? A Comprehensive Review.

PURPOSE: The landscape of ureteroscopy has been transformed by rapid advancements in laser technology. The transition from the standard Holmium:YAG (Ho:YAG) to Thulium Fiber Laser (TFL) and emerging hybrid technologies (Magneto/Tm:YAG) creates decisional uncertainty. This review analyzes the physical principles, safety, and clinical outcomes of available lasers, proposing a context-based decision-making framework. MATERIALS AND METHODS: A literature review using PubMed and Embase (2014-2025) yielded 1,902 records. Search terms included "holmium laser nephrolithotripsy," "thulium fiber laser," and "ureteroscopy laser." Fourteen seminal high-quality studies were selected for expert narrative synthesis, focusing on ablation efficiency, stone-free rates (SFR), complications, and cost-effectiveness. RESULTS: Literature heterogeneity, particularly inconsistent SFR definitions and imaging modalities, challenges comparative analysis. Clinically, TFL demonstrates superior ablation speeds and dusting capabilities compared to standard Ho:YAG, with equivalent safety. However, High-Power Ho:YAG remains unmatched in versatility for complex stones. Emerging pulsed Tm:YAG and Magneto Cyber Ho systems theoretically combine peak power with dusting efficiency but require further validation. Economically, TFL and High-Power systems demand significantly higher capital investment than Low-Power alternatives. CONCLUSIONS: No universally superior laser exists; selection must be guided by institutional context. We propose a four-scenario framework: (1) Low-Power Ho:YAG is ideal for cost-sensitive, low-volume centers; (2) High-Power Ho:YAG is the standard for high-volume centers treating complex cases; (3) TFL is the choice for maximizing operative efficiency and dusting; and (4) Emerging Hybrid Technologies suit academic centers driving innovation. Future studies must prioritize standardized reporting to solidify the evidence base.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-07-16
DOI
https://doi.org/10.1590/s1677-5538.ibju.2026.0195
Primary Topic
Kidney Stones and Urolithiasis Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Which is the best laser for ureteroscopy? A Comprehensive Review.

Giovanni Scala Marchini, Carlos Alfredo Battagello, Vinícius Ravena Lourenço, João Pedro Leal Puppin et al.
PubMed
Kidney Stones and Urolithiasis Treatments
article

Which is the best laser for ureteroscopy? A Comprehensive Review.

Giovanni Scala Marchini, Carlos Alfredo Battagello, Vinícius Ravena Lourenço, João Pedro Leal Puppin, Fábio César Miranda Torricelli, Anderson Pellanda, William Carlos Nahas, Fábio Carvalho Vicentini, Alexandre Danilovic, Rodrigo Perrella, Eduardo Mazzucchi
article en

Abstract

PURPOSE: The landscape of ureteroscopy has been transformed by rapid advancements in laser technology. The transition from the standard Holmium:YAG (Ho:YAG) to Thulium Fiber Laser (TFL) and emerging hybrid technologies (Magneto/Tm:YAG) creates decisional uncertainty. This review analyzes the physical principles, safety, and clinical outcomes of available lasers, proposing a context-based decision-making framework. MATERIALS AND METHODS: A literature review using PubMed and Embase (2014-2025) yielded 1,902 records. Search terms included "holmium laser nephrolithotripsy," "thulium fiber laser," and "ureteroscopy laser." Fourteen seminal high-quality studies were selected for expert narrative synthesis, focusing on ablation efficiency, stone-free rates (SFR), complications, and cost-effectiveness. RESULTS: Literature heterogeneity, particularly inconsistent SFR definitions and imaging modalities, challenges comparative analysis. Clinically, TFL demonstrates superior ablation speeds and dusting capabilities compared to standard Ho:YAG, with equivalent safety. However, High-Power Ho:YAG remains unmatched in versatility for complex stones. Emerging pulsed Tm:YAG and Magneto Cyber Ho systems theoretically combine peak power with dusting efficiency but require further validation. Economically, TFL and High-Power systems demand significantly higher capital investment than Low-Power alternatives. CONCLUSIONS: No universally superior laser exists; selection must be guided by institutional context. We propose a four-scenario framework: (1) Low-Power Ho:YAG is ideal for cost-sensitive, low-volume centers; (2) High-Power Ho:YAG is the standard for high-volume centers treating complex cases; (3) TFL is the choice for maximizing operative efficiency and dusting; and (4) Emerging Hybrid Technologies suit academic centers driving innovation. Future studies must prioritize standardized reporting to solidify the evidence base.

PubMedVol. 52(4)
Universidade de São Paulo (BR), Centro Universitário das Faculdades Metropolitanas Unidas (BR), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (BR)
Industry, innovation and infrastructure
Openalex Percentile: Top 46%
Kidney Stones and Urolithiasis Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.