Accuracy of digital inclinometers for measuring knee extension during total knee arthroplasty: comparison with visual estimation and computer navigation

BACKGROUND: Accurate intra-operative assessment of knee extension angle is essential in total knee arthroplasty (TKA), as residual flexion contracture or hyperextension is associated with inferior post-operative function and increased implant wear. Visual estimation remains widely used, but prior research has demonstrated substantial inaccuracy. This study evaluated the accuracy and reliability of a digital inclinometer technique for measuring knee extension angle during TKA, using computer navigation as the reference standard. METHODS: A prospective comparative study was performed on 130 knees undergoing primary posterior-stabilized TKA. After trial implant insertion, knee extension was assessed using two methods: visual estimation and a digital inclinometer method utilizing the femoral chisel holder and anterior border of the tibial crest. All measurements were compared with OrthoPilot navigation. Accuracy was defined as measurements within ± 2° of navigation. Correlation, agreement, and intra- and inter-observer reliability were evaluated. RESULTS: = 0.799; both p < 0.001). Bland-Altman analysis demonstrated minimal bias and no proportional error for the inclinometer, whereas visual estimation showed wide limits of agreement. Intra- and inter-observer reliability for inclinometer measurements was excellent (ICCs of 0.91 and 0.93), superior to visual estimation. CONCLUSION: The digital inclinometer technique provides accurate and reproducible intra-operative knee extension measurements, outperforming visual estimation and approximating navigation-based assessment. This low-cost approach is feasible where navigation is unavailable. TRIAL REGISTRATION: Thai Clinical Trials Registry (TCTR20180828002). Registered on 28 August 2018. Prospectively registered.

Authors

Institutions

Publication Details

Journal
Arthroplasty
Published
2026-05-12
DOI
https://doi.org/10.1186/s42836-026-00392-9
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of digital inclinometers for measuring knee extension during total knee arthroplasty: comparison with visual estimation and computer navigation

Chonlathan Iamsumang, Siripong Tahwang, Anuwat Pongkunakorn, Rukthanin Ruktrakul et al.
Arthroplasty
Total Knee Arthroplasty Outcomes
article

Accuracy of digital inclinometers for measuring knee extension during total knee arthroplasty: comparison with visual estimation and computer navigation

Chonlathan Iamsumang, Siripong Tahwang, Anuwat Pongkunakorn, Rukthanin Ruktrakul, Phatcharapon Udomluck, Sayun Sumethvanich
article en

Abstract

BACKGROUND: Accurate intra-operative assessment of knee extension angle is essential in total knee arthroplasty (TKA), as residual flexion contracture or hyperextension is associated with inferior post-operative function and increased implant wear. Visual estimation remains widely used, but prior research has demonstrated substantial inaccuracy. This study evaluated the accuracy and reliability of a digital inclinometer technique for measuring knee extension angle during TKA, using computer navigation as the reference standard. METHODS: A prospective comparative study was performed on 130 knees undergoing primary posterior-stabilized TKA. After trial implant insertion, knee extension was assessed using two methods: visual estimation and a digital inclinometer method utilizing the femoral chisel holder and anterior border of the tibial crest. All measurements were compared with OrthoPilot navigation. Accuracy was defined as measurements within ± 2° of navigation. Correlation, agreement, and intra- and inter-observer reliability were evaluated. RESULTS: = 0.799; both p < 0.001). Bland-Altman analysis demonstrated minimal bias and no proportional error for the inclinometer, whereas visual estimation showed wide limits of agreement. Intra- and inter-observer reliability for inclinometer measurements was excellent (ICCs of 0.91 and 0.93), superior to visual estimation. CONCLUSION: The digital inclinometer technique provides accurate and reproducible intra-operative knee extension measurements, outperforming visual estimation and approximating navigation-based assessment. This low-cost approach is feasible where navigation is unavailable. TRIAL REGISTRATION: Thai Clinical Trials Registry (TCTR20180828002). Registered on 28 August 2018. Prospectively registered.

ArthroplastyVol. 8(1)
University of Phayao (TH), Lampang Hospital (TH)
Openalex Percentile: Top 4%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.