Performance Enhancement of Pre-loaded RC Short Columns Damaged by High Temperature Using CFRP Wrapping

Introduction This study investigates the effectiveness of rehabilitating fire-damaged reinforced concrete (RC) short columns by removing the deteriorated concrete cover, replacing it with normal concrete (NC), and strengthening the columns using carbon fiber reinforced polymer (CFRP) sheets. Methods An experimental program was conducted on nine small-scale RC column specimens subjected to eccentric axial loading with an eccentricity of 45 mm. The columns were exposed to fire temperatures of 500 °C and 700 °C for durations of 60 min and 120 min using a specially designed furnace, while sustaining a constant axial load equal to 50% Pu. An unexposed control specimen was tested for comparison. After fire exposure, the damaged concrete cover was removed and replaced with NC, followed by full wrapping using CFRP sheets. Results The results showed a significant reduction in ultimate load capacity with increasing fire temperature and exposure duration. Fire-exposed specimens exhibited noticeable strength degradation compared to the control specimen. After rehabilitation using NC replacement and CFRP wrapping, the columns demonstrated substantial recovery and enhancement in load-carrying capacity. Discussion The improvement in structural performance is attributed to the confinement effect provided by CFRP sheets combined with the restored concrete cover. The results also highlight the influence of fire severity on residual strength and confirm the effectiveness of the proposed rehabilitation technique under eccentric loading conditions. Conclusion Replacing the damaged concrete cover with NC and strengthening with CFRP sheets proved to be an effective rehabilitation technique for fire-damaged RC columns. The proposed method significantly restored and enhanced load-carrying capacity, supporting its practical application for post-fire strengthening under sustained eccentric loads.

Authors

Institutions

Publication Details

Journal
The Open Civil Engineering Journal
Published
2026-05-12
DOI
https://doi.org/10.2174/0118741495481542260506072418
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Enhancement of Pre-loaded RC Short Columns Damaged by High Temperature Using CFRP Wrapping

Ahlam Sader Mohammed, Sarmad Shafeeq Abdulqader, Mohanad Wisam Mousa
The Open Civil Engineering Journal
Fire effects on concrete materials
article

Performance Enhancement of Pre-loaded RC Short Columns Damaged by High Temperature Using CFRP Wrapping

Ahlam Sader Mohammed, Sarmad Shafeeq Abdulqader, Mohanad Wisam Mousa
article en

Abstract

Introduction This study investigates the effectiveness of rehabilitating fire-damaged reinforced concrete (RC) short columns by removing the deteriorated concrete cover, replacing it with normal concrete (NC), and strengthening the columns using carbon fiber reinforced polymer (CFRP) sheets. Methods An experimental program was conducted on nine small-scale RC column specimens subjected to eccentric axial loading with an eccentricity of 45 mm. The columns were exposed to fire temperatures of 500 °C and 700 °C for durations of 60 min and 120 min using a specially designed furnace, while sustaining a constant axial load equal to 50% Pu. An unexposed control specimen was tested for comparison. After fire exposure, the damaged concrete cover was removed and replaced with NC, followed by full wrapping using CFRP sheets. Results The results showed a significant reduction in ultimate load capacity with increasing fire temperature and exposure duration. Fire-exposed specimens exhibited noticeable strength degradation compared to the control specimen. After rehabilitation using NC replacement and CFRP wrapping, the columns demonstrated substantial recovery and enhancement in load-carrying capacity. Discussion The improvement in structural performance is attributed to the confinement effect provided by CFRP sheets combined with the restored concrete cover. The results also highlight the influence of fire severity on residual strength and confirm the effectiveness of the proposed rehabilitation technique under eccentric loading conditions. Conclusion Replacing the damaged concrete cover with NC and strengthening with CFRP sheets proved to be an effective rehabilitation technique for fire-damaged RC columns. The proposed method significantly restored and enhanced load-carrying capacity, supporting its practical application for post-fire strengthening under sustained eccentric loads.

The Open Civil Engineering JournalVol. 20(1)
University of Technology - Iraq (IQ)
Sustainable cities and communities
Openalex Percentile: Top 8%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Enhancement of Pre-loaded RC Short Columns Damaged by High Temperature Using CFRP Wrapping — Ahlam Sader Mohammed, Sarmad Shafeeq Abdulqader, et al. · The Open Civil Engineering Journal (2026) | TGRS Research Map | TGRS