Field‐Based Spatial Self‐Registration of Multicoil Hardware for <scp> B <sub>0</sub> </scp> Field Control

PURPOSE: field control despite nonreproducible hardware placement between calibration and experimental sessions. METHODS: An algorithm was designed to estimate rigid transformations between 3D field maps acquired during hardware calibration (Reference field) and subsequent experiments (Measured field). Hardware misplacement was determined by co-registration of the two fields within a defined region of interest. Simulations using Biot-Savart-derived MC basis fields and experimental validation with a 48-channel MC array at 3 T were used to quantify localization accuracy under varying signal-to-noise ratio (SNR) levels. A genetic algorithm optimized coil currents to generate a Reference field shape that yielded minimal self-registration error. RESULTS: Simulations and measurements demonstrated that submillimeter (≤ 0.5 mm) and subdegree (≤ 0.5°) localization accuracy is achievable at practical SNR levels (≥ 5). Errors decreased with increasing SNR and field complexity. The optimized field produced by the genetic algorithm yielded the lowest mean translation error (0.20 mm) and rotation error (0.11°), consistent with theoretical predictions. Self-registration computation required less than 10 s per case. CONCLUSION: shimming performance in insert-based or repositionable MR systems.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-05-12
DOI
https://doi.org/10.1002/mrm.70413
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Field‐Based Spatial Self‐Registration of Multicoil Hardware for B 0 Field Control

Carlotta Ianniello, Christoph Juchem, Sebastian Theilenberg, Isabelle Zinghini et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

Field‐Based Spatial Self‐Registration of Multicoil Hardware for B 0 Field Control

Carlotta Ianniello, Christoph Juchem, Sebastian Theilenberg, Isabelle Zinghini, Ian Macleod
article en

Abstract

PURPOSE: field control despite nonreproducible hardware placement between calibration and experimental sessions. METHODS: An algorithm was designed to estimate rigid transformations between 3D field maps acquired during hardware calibration (Reference field) and subsequent experiments (Measured field). Hardware misplacement was determined by co-registration of the two fields within a defined region of interest. Simulations using Biot-Savart-derived MC basis fields and experimental validation with a 48-channel MC array at 3 T were used to quantify localization accuracy under varying signal-to-noise ratio (SNR) levels. A genetic algorithm optimized coil currents to generate a Reference field shape that yielded minimal self-registration error. RESULTS: Simulations and measurements demonstrated that submillimeter (≤ 0.5 mm) and subdegree (≤ 0.5°) localization accuracy is achievable at practical SNR levels (≥ 5). Errors decreased with increasing SNR and field complexity. The optimized field produced by the genetic algorithm yielded the lowest mean translation error (0.20 mm) and rotation error (0.11°), consistent with theoretical predictions. Self-registration computation required less than 10 s per case. CONCLUSION: shimming performance in insert-based or repositionable MR systems.

Magnetic Resonance in Medicine
Yale University (US), New York University (US), Medical University of Vienna (AT), Columbia University (US)
National Institutes of Health
Openalex Percentile: Top 5%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Field‐Based Spatial Self‐Registration of Multicoil Hardware for <scp> B <sub>0</sub> </scp> Field Control — Carlotta Ianniello, Christoph Juchem, et al. · Magnetic Resonance in Medicine (2026) | TGRS Research Map | TGRS