Aerosol Jet Printed Ion-Selective Electrodes for Potassium Detection

This work evaluates a potassium ion-selective electrode (K-ISE) fabricated using Aerosol Jet Printing (AJP) and compares its performance with that of a commercial K+-selective electrode (KION). Both sensors exhibit near-Nernstian behavior, with average sensitivities of 57.91 ± 5.07 mV/dec for the AJP device and 57.28 ± 5.07 mV/dec for the commercial electrode, confirming a near-Nernstian K+ response over the tested concentration range. Single-interferent response tests demonstrate that AJP-printed electrodes provide a more stable and less sensitive response to sodium interference (24.37 ± 1.39 mV/dec) compared to KION (33.95 ± 8.95 mV/dec), while showing comparable NH4+ response and a slightly higher response toward urea than KION. Morphological analysis (OM and SEM) reveals that AJP enables smoother, more homogeneous films and improved control over the transducer/membrane interface. Unlike previous studies, this work presents a direct experimental comparison between AJP-fabricated and commercial ISEs under controlled interference conditions relevant to agricultural and environmental matrices. Although the AJP sensors exhibited near-Nernstian behavior and fast response times, their reproducibility was lower than that of the commercial electrodes (RSD = 30.12% vs. 18.45%), indicating that further optimization of the printing and membrane deposition processes is required.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-05-12
DOI
https://doi.org/10.3390/s26103053
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aerosol Jet Printed Ion-Selective Electrodes for Potassium Detection

Mauro Serpelloni, Emilio Sardini, Giorgia Polidori
Sensors
Analytical Chemistry and Sensors
article

Aerosol Jet Printed Ion-Selective Electrodes for Potassium Detection

Mauro Serpelloni, Emilio Sardini, Giorgia Polidori
article en

Abstract

This work evaluates a potassium ion-selective electrode (K-ISE) fabricated using Aerosol Jet Printing (AJP) and compares its performance with that of a commercial K+-selective electrode (KION). Both sensors exhibit near-Nernstian behavior, with average sensitivities of 57.91 ± 5.07 mV/dec for the AJP device and 57.28 ± 5.07 mV/dec for the commercial electrode, confirming a near-Nernstian K+ response over the tested concentration range. Single-interferent response tests demonstrate that AJP-printed electrodes provide a more stable and less sensitive response to sodium interference (24.37 ± 1.39 mV/dec) compared to KION (33.95 ± 8.95 mV/dec), while showing comparable NH4+ response and a slightly higher response toward urea than KION. Morphological analysis (OM and SEM) reveals that AJP enables smoother, more homogeneous films and improved control over the transducer/membrane interface. Unlike previous studies, this work presents a direct experimental comparison between AJP-fabricated and commercial ISEs under controlled interference conditions relevant to agricultural and environmental matrices. Although the AJP sensors exhibited near-Nernstian behavior and fast response times, their reproducibility was lower than that of the commercial electrodes (RSD = 30.12% vs. 18.45%), indicating that further optimization of the printing and membrane deposition processes is required.

SensorsVol. 26(10)
University of Brescia (IT)
European Commission
Zero hunger
Openalex Percentile: Top 9%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Aerosol Jet Printed Ion-Selective Electrodes for Potassium Detection — Mauro Serpelloni, Emilio Sardini, et al. · Sensors (2026) | TGRS Research Map | TGRS