Effects of Pre-Dialysis Fluid Overload, Intradialytic Relative Blood Volume Levels and Cumulative Ultrafiltration Volume on Pulse Wave-Derived Features during Hemodialysis: Results from a Longitudinal Cohort Study

INTRODUCTION: Arterial pulse wave features (PWFs) reflect hemodynamic changes during hemodialysis and, while their use is not currently recommended by clinical practice guidelines, many PWFs are associated with patient outcomes beyond classical blood pressure measurements. Pre-dialysis fluid overload (FO), intradialytic relative blood volume (RBV), and cumulative ultrafiltration volume (cUFV) may influence PWFs, but these relationships remain incompletely characterized. We aimed to explore associations between FO, RBV, cUFV, and PWFs during hemodialysis. METHODS: We analyzed 79 hemodialysis sessions in 24 patients over five weeks. Each session included pre-dialysis bioimpedance spectroscopy, cuff-based pulse wave measurements every 15 minutes, and continuous RBV/cUFV monitoring. Associations between RBV or cUFV and 28 PWFs (including blood pressure measures, parameters of cardiac function, and various arterial wave features derived from pulse wave analysis) were assessed using confounder-adjusted generalized estimating equations. Repeated-measures correlation analysis evaluated within-patient associations between pre-dialysis FO and both initial PWF levels (median from the first 45 minutes) and their intradialytic changes (late minus early 45-minute median). RESULTS: We analyzed 817 pulse wave measurements from 24 patients (21 men; median age 66 years). RBV was associated with 18/28 PWFs (64%), whereas cUFV was associated with 10/28 (36%), with distinct patterns: associations with RBV were observed mainly for the cardiac function parameters (stroke volume, cardiac output, heart rate) and arterial wave components (forward/backward wave amplitudes, wave intensity peaks, reflection coefficient), while associations with cUFV were observed mainly for diastolic blood pressure, peripheral resistance, and reservoir pressure. Significant early-to-late intradialytic changes in PWFs included a decrease in stroke volume, reflection coefficient and cardiac output, as well as an increase in pulse pressure amplification and reflected intensity peak. Among initial PWF levels, only the excess pressure integral correlated with pre-dialysis FO; however, FO correlated positively with intradialytic changes in systolic and mean blood pressure, pulse wave velocity, and reservoir pressure, indicating attenuated decreases in these parameters when baseline fluid excess was higher. CONCLUSION: In the studied cohort, RBV and cUFV showed distinct association profiles with PWFs during hemodialysis. These relationships warrant consideration in studies assessing or intervening on PWFs in dialysis patients.

Authors

Publication Details

Journal
Kidney & Blood Pressure Research
Published
2026-05-12
DOI
https://doi.org/10.1159/000552495
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Pre-Dialysis Fluid Overload, Intradialytic Relative Blood Volume Levels and Cumulative Ultrafiltration Volume on Pulse Wave-Derived Features during Hemodialysis: Results from a Longitudinal Cohort Study

Amelie Kurnikowski, Simon Krenn, Leszek Pstras, Christopher Mayer et al.
Kidney & Blood Pressure Research
Dialysis and Renal Disease Management
article

Effects of Pre-Dialysis Fluid Overload, Intradialytic Relative Blood Volume Levels and Cumulative Ultrafiltration Volume on Pulse Wave-Derived Features during Hemodialysis: Results from a Longitudinal Cohort Study

Amelie Kurnikowski, Simon Krenn, Leszek Pstras, Christopher Mayer, Siegfried Wassertheurer, Sebastian Mussnig, Manfred Hecking
article en

Abstract

INTRODUCTION: Arterial pulse wave features (PWFs) reflect hemodynamic changes during hemodialysis and, while their use is not currently recommended by clinical practice guidelines, many PWFs are associated with patient outcomes beyond classical blood pressure measurements. Pre-dialysis fluid overload (FO), intradialytic relative blood volume (RBV), and cumulative ultrafiltration volume (cUFV) may influence PWFs, but these relationships remain incompletely characterized. We aimed to explore associations between FO, RBV, cUFV, and PWFs during hemodialysis. METHODS: We analyzed 79 hemodialysis sessions in 24 patients over five weeks. Each session included pre-dialysis bioimpedance spectroscopy, cuff-based pulse wave measurements every 15 minutes, and continuous RBV/cUFV monitoring. Associations between RBV or cUFV and 28 PWFs (including blood pressure measures, parameters of cardiac function, and various arterial wave features derived from pulse wave analysis) were assessed using confounder-adjusted generalized estimating equations. Repeated-measures correlation analysis evaluated within-patient associations between pre-dialysis FO and both initial PWF levels (median from the first 45 minutes) and their intradialytic changes (late minus early 45-minute median). RESULTS: We analyzed 817 pulse wave measurements from 24 patients (21 men; median age 66 years). RBV was associated with 18/28 PWFs (64%), whereas cUFV was associated with 10/28 (36%), with distinct patterns: associations with RBV were observed mainly for the cardiac function parameters (stroke volume, cardiac output, heart rate) and arterial wave components (forward/backward wave amplitudes, wave intensity peaks, reflection coefficient), while associations with cUFV were observed mainly for diastolic blood pressure, peripheral resistance, and reservoir pressure. Significant early-to-late intradialytic changes in PWFs included a decrease in stroke volume, reflection coefficient and cardiac output, as well as an increase in pulse pressure amplification and reflected intensity peak. Among initial PWF levels, only the excess pressure integral correlated with pre-dialysis FO; however, FO correlated positively with intradialytic changes in systolic and mean blood pressure, pulse wave velocity, and reservoir pressure, indicating attenuated decreases in these parameters when baseline fluid excess was higher. CONCLUSION: In the studied cohort, RBV and cUFV showed distinct association profiles with PWFs during hemodialysis. These relationships warrant consideration in studies assessing or intervening on PWFs in dialysis patients.

Kidney & Blood Pressure Research
Vienna Science and Technology Fund, Universität Wien, Medizinische Universität Wien, Austrian Institute of Technology
Good health and well-being
Openalex Percentile: Top 6%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.