A Unified Computational-Experimental Paradigm for Rational Design of Next-Generation Electrochemical Biosensors: The IECM Framework

Electrochemical sensors face critical challenges in achieving ultra-high sensitivity and specificity within complex biological matrices. To address these limitations, this study proposes an Integrated Electrochemical Computational Model (IECM), a novel end-to-end framework that couples kinetics, electrochemistry, and signal amplification sub-modules to predict and optimize sensor performance. Unlike previous descriptive reviews, this work validates the IECM through rigorous experimentation using rGO/MXene/AuNP nanocomposite interfaces. The limit of detection (LOD) was determined based on the standard definition (3sigma/slope, where sigma is the standard deviation of the blank signal), yielding exceptionally low values of 0.12 fg/mL for prostate-specific antigen (PSA) and 5.0 × 10⁻¹⁸ M for microRNA-21, with corresponding calibration curve slopes confirming high signal-to-noise ratios. In complex matrices such as serum and saliva, the sensor demonstrated robust anti-interference capabilities, achieving recovery rates of 92.0% ± 3.5% and cross-reactivity rates below 3.5%. Long-term stability tests indicated a signal retention of 68.7% after 8 weeks under moderate storage conditions. Furthermore, double-blind clinical trials against gold-standard assays revealed a high concordance rate (κ = 0.93), confirming the model's predictive accuracy and the sensor's clinical potential. This research establishes a unified computational-experimental paradigm for the rational design of next-generation biosensors.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-05-12
DOI
https://doi.org/10.1088/2057-1976/ae6c2e
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Unified Computational-Experimental Paradigm for Rational Design of Next-Generation Electrochemical Biosensors: The IECM Framework

Tong’en Zhang, Yuanyuan Xu, Zheng Wei, Cong Yu
Biomedical Physics & Engineering Express
Advanced biosensing and bioanalysis techniques
article

A Unified Computational-Experimental Paradigm for Rational Design of Next-Generation Electrochemical Biosensors: The IECM Framework

Tong’en Zhang, Yuanyuan Xu, Zheng Wei, Cong Yu
article en

Abstract

Electrochemical sensors face critical challenges in achieving ultra-high sensitivity and specificity within complex biological matrices. To address these limitations, this study proposes an Integrated Electrochemical Computational Model (IECM), a novel end-to-end framework that couples kinetics, electrochemistry, and signal amplification sub-modules to predict and optimize sensor performance. Unlike previous descriptive reviews, this work validates the IECM through rigorous experimentation using rGO/MXene/AuNP nanocomposite interfaces. The limit of detection (LOD) was determined based on the standard definition (3sigma/slope, where sigma is the standard deviation of the blank signal), yielding exceptionally low values of 0.12 fg/mL for prostate-specific antigen (PSA) and 5.0 × 10⁻¹⁸ M for microRNA-21, with corresponding calibration curve slopes confirming high signal-to-noise ratios. In complex matrices such as serum and saliva, the sensor demonstrated robust anti-interference capabilities, achieving recovery rates of 92.0% ± 3.5% and cross-reactivity rates below 3.5%. Long-term stability tests indicated a signal retention of 68.7% after 8 weeks under moderate storage conditions. Furthermore, double-blind clinical trials against gold-standard assays revealed a high concordance rate (κ = 0.93), confirming the model's predictive accuracy and the sensor's clinical potential. This research establishes a unified computational-experimental paradigm for the rational design of next-generation biosensors.

Biomedical Physics & Engineering Express
Henan Institute of Technology (CN), Henan Institute of Science and Technology (CN), Xinxiang University (CN), Henan Medical University (CN)
Openalex Percentile: Top 8%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Unified Computational-Experimental Paradigm for Rational Design of Next-Generation Electrochemical Biosensors: The IECM Framework — Tong’en Zhang, Yuanyuan Xu, et al. · Biomedical Physics & Engineering Express (2026) | TGRS Research Map | TGRS