Biomechanical Comparison of 4 Radial Meniscal Repair Techniques Including a Novel Dual Tie-Grip Configuration

BACKGROUND: Complex repairs of radial meniscal tears have shown increased fixation strength compared to conventional sutures. A simplified 2-suture hybrid and a novel dual tie-grip repair with interconnected vertical mattress sutures spanning the tear were tested and compared to all-inside double-horizontal and tie-grip repairs. HYPOTHESIS: The dual tie-grip repair would increase the initial compression load across the tear and show the least cyclic displacement and highest failure strength. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 40 porcine medial menisci were assigned to 4 repair groups: double-horizontal, hybrid, tie-grip, and dual tie-grip (10 per group). Results from tie-grip repairs were used to assess the effect of vertical mattress suture interconnection. After suture placement according to the described technique and fixation, the initial compressive load, stiffness, and relief displacement were measured. The repaired specimens underwent cyclic loading between 5 and 30 N over 1000 cycles (0.75 Hz), while cyclic stiffness and displacement were measured. Ultimate stiffness and load-to-failure were analyzed at 3.15 mm/s. RESULTS: < .001). CONCLUSION: The dual tie-grip repair provided the highest initial compression across the radial meniscal tear, the lowest cyclic displacement, and the greatest load-to-failure among all techniques in a porcine cadaveric model. The simplified 2-suture hybrid repair showed higher initial compression than other repairs and comparable cyclic stability to the tie-grip repair. CLINICAL RELEVANCE: The dual tie-grip repair provided high compression across the radial tear and strong resistance to cyclic displacement. Future clinical series assessing differences in healing rates among different repair groups are warranted.

Authors

Institutions

Publication Details

Journal
The American Journal of Sports Medicine
Published
2026-05-11
DOI
https://doi.org/10.1177/03635465261439079
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Comparison of 4 Radial Meniscal Repair Techniques Including a Novel Dual Tie-Grip Configuration

Samuel Bachmaier, Patrick A. Smith, Asheesh Bedi, P Müller et al.
The American Journal of Sports Medicine
Knee injuries and reconstruction techniques
article

Biomechanical Comparison of 4 Radial Meniscal Repair Techniques Including a Novel Dual Tie-Grip Configuration

Samuel Bachmaier, Patrick A. Smith, Asheesh Bedi, P Müller, Aaron J. Krych
article en

Abstract

BACKGROUND: Complex repairs of radial meniscal tears have shown increased fixation strength compared to conventional sutures. A simplified 2-suture hybrid and a novel dual tie-grip repair with interconnected vertical mattress sutures spanning the tear were tested and compared to all-inside double-horizontal and tie-grip repairs. HYPOTHESIS: The dual tie-grip repair would increase the initial compression load across the tear and show the least cyclic displacement and highest failure strength. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 40 porcine medial menisci were assigned to 4 repair groups: double-horizontal, hybrid, tie-grip, and dual tie-grip (10 per group). Results from tie-grip repairs were used to assess the effect of vertical mattress suture interconnection. After suture placement according to the described technique and fixation, the initial compressive load, stiffness, and relief displacement were measured. The repaired specimens underwent cyclic loading between 5 and 30 N over 1000 cycles (0.75 Hz), while cyclic stiffness and displacement were measured. Ultimate stiffness and load-to-failure were analyzed at 3.15 mm/s. RESULTS: < .001). CONCLUSION: The dual tie-grip repair provided the highest initial compression across the radial meniscal tear, the lowest cyclic displacement, and the greatest load-to-failure among all techniques in a porcine cadaveric model. The simplified 2-suture hybrid repair showed higher initial compression than other repairs and comparable cyclic stability to the tie-grip repair. CLINICAL RELEVANCE: The dual tie-grip repair provided high compression across the radial tear and strong resistance to cyclic displacement. Future clinical series assessing differences in healing rates among different repair groups are warranted.

The American Journal of Sports Medicine
Hospital for Special Surgery (US), Mayo Clinic (US), University of Michigan (US), Naples Community Hospital Healthcare System (US), WinnMed (US), Arthrex (Germany) (DE), Ludwig-Maximilians-Universität München (DE)
Arthrex GmbH
Openalex Percentile: Top 4%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.