Selective Recognition of Tumor-Derived EVs by EpCAM-Imprinted Polymers for Proteomic Biomarker Discovery

μg/g and an imprinting factor of 6.02, demonstrating excellent template recognition. At the cellular level, MIP selectively bound to EpCAM-high tumor cells (e.g., PANC-1, HeLa) while showing negligible adsorption to normal cells (293T), confirming its targeting specificity. Proteomic analysis of preoperative versus postoperative urine samples and matched tumor versus peritumor tissues revealed that MIP-captured EVs reliably reflect tumor status, with tumor-associated proteins such as GPC1 and TIMP1 exhibiting consistent expression changes across both sample types. In summary, this study establishes a method for specific capture of EpCAM+ EVs in complex biological environments. The low cost and high stability of the MIP material offer a novel tool for liquid biopsy. With further validation using large-scale clinical samples, this approach may have potential for advancing EpCAM+ EV-based early diagnosis of malignant tumors such as pancreatic cancer (PC) and for enabling new strategies in tumor microenvironment research and personalized therapy.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-05-12
DOI
https://doi.org/10.1021/acs.analchem.6c01944
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Selective Recognition of Tumor-Derived EVs by EpCAM-Imprinted Polymers for Proteomic Biomarker Discovery

Shilong Zhao, Lu Hu, Fengxiang Lou, Wenjing Yu et al.
Analytical Chemistry
Analytical chemistry methods development
article

Selective Recognition of Tumor-Derived EVs by EpCAM-Imprinted Polymers for Proteomic Biomarker Discovery

Shilong Zhao, Lu Hu, Fengxiang Lou, Wenjing Yu, Feng Wei, Luxi Chen
article en

Abstract

μg/g and an imprinting factor of 6.02, demonstrating excellent template recognition. At the cellular level, MIP selectively bound to EpCAM-high tumor cells (e.g., PANC-1, HeLa) while showing negligible adsorption to normal cells (293T), confirming its targeting specificity. Proteomic analysis of preoperative versus postoperative urine samples and matched tumor versus peritumor tissues revealed that MIP-captured EVs reliably reflect tumor status, with tumor-associated proteins such as GPC1 and TIMP1 exhibiting consistent expression changes across both sample types. In summary, this study establishes a method for specific capture of EpCAM+ EVs in complex biological environments. The low cost and high stability of the MIP material offer a novel tool for liquid biopsy. With further validation using large-scale clinical samples, this approach may have potential for advancing EpCAM+ EV-based early diagnosis of malignant tumors such as pancreatic cancer (PC) and for enabling new strategies in tumor microenvironment research and personalized therapy.

Analytical Chemistry
OSRAM (United States) (US), Jilin University (CN), First Hospital of Jilin University (CN), Jilin Medical University (CN)
National Natural Science Foundation of China, Department of Science and Technology of Jilin Province
Openalex Percentile: Top 7%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Selective Recognition of Tumor-Derived EVs by EpCAM-Imprinted Polymers for Proteomic Biomarker Discovery — Shilong Zhao, Lu Hu, et al. · Analytical Chemistry (2026) | TGRS Research Map | TGRS