Diamond-Coated Manual Curettes Improve Simulated Root Deposit Removal: An In Vitro Comparative Pilot Study

Background: The effectiveness of non-surgical periodontal therapy largely depends on the ability of instruments to efficiently remove plaque and calculus from root surfaces. In recent years, innovative instruments such as LM Sharp Diamond™ curettes have been introduced, featuring a coated blade that maintains sharpness without the need for resharpening. The aim of this pilot in vitro study was to compare the cleaning efficacy of LM Sharp Diamond curettes with that of conventional stainless-steel curettes, hypothesizing that the diamond-coated instruments would demonstrate superior deposit removal efficiency. Materials and Methods: Extracted teeth were selected, fixed on a support, and the root surfaces were coated with black varnish to simulate plaque and calculus deposits. Standardized photographs were taken at baseline (T0). The coated root surfaces were then instrumented using LM Sharp Diamond™ curettes (test group) or traditional Gracey curettes (control group). After treatment (T1), the images were analyzed with Image Color Summarizer software 0.82 to calculate the percentage of cleaned surface. The results were subjected to statistical analysis performed by a professional statistician. Results: The results, obtained from the treatment of nine surfaces, demonstrated that LM Sharp Diamond™ curettes achieved greater and more consistent removal efficiency, with a mean reduction of 1.27 percentage points in residual coated area (RCA) deposits compared to traditional curettes (p = 4.45 × 10−6). Conclusions: Preliminary evidence suggests that LM Sharp Diamond™ curettes may ensure more effective residue removal than traditional steel curettes. Statistically, it has been shown that LM Sharp Diamond™ curettes provide a cleaner and more uniform surface than traditional steel curettes.

Authors

Institutions

Publication Details

Journal
Hygiene
Published
2026-05-12
DOI
https://doi.org/10.3390/hygiene6020025
Primary Topic
Periodontal Regeneration and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diamond-Coated Manual Curettes Improve Simulated Root Deposit Removal: An In Vitro Comparative Pilot Study

Sergio Mazzoleni, Marco Rossi, Ernesto Comitale, Roberta Gaia Parcianello et al.
Hygiene
Periodontal Regeneration and Treatments
article

Diamond-Coated Manual Curettes Improve Simulated Root Deposit Removal: An In Vitro Comparative Pilot Study

Sergio Mazzoleni, Marco Rossi, Ernesto Comitale, Roberta Gaia Parcianello, Davide Scettri, Giulia Gargano, Edoardo Stellini, Valentina Brun, Francesco Saverio Ludovichetti
article en

Abstract

Background: The effectiveness of non-surgical periodontal therapy largely depends on the ability of instruments to efficiently remove plaque and calculus from root surfaces. In recent years, innovative instruments such as LM Sharp Diamond™ curettes have been introduced, featuring a coated blade that maintains sharpness without the need for resharpening. The aim of this pilot in vitro study was to compare the cleaning efficacy of LM Sharp Diamond curettes with that of conventional stainless-steel curettes, hypothesizing that the diamond-coated instruments would demonstrate superior deposit removal efficiency. Materials and Methods: Extracted teeth were selected, fixed on a support, and the root surfaces were coated with black varnish to simulate plaque and calculus deposits. Standardized photographs were taken at baseline (T0). The coated root surfaces were then instrumented using LM Sharp Diamond™ curettes (test group) or traditional Gracey curettes (control group). After treatment (T1), the images were analyzed with Image Color Summarizer software 0.82 to calculate the percentage of cleaned surface. The results were subjected to statistical analysis performed by a professional statistician. Results: The results, obtained from the treatment of nine surfaces, demonstrated that LM Sharp Diamond™ curettes achieved greater and more consistent removal efficiency, with a mean reduction of 1.27 percentage points in residual coated area (RCA) deposits compared to traditional curettes (p = 4.45 × 10−6). Conclusions: Preliminary evidence suggests that LM Sharp Diamond™ curettes may ensure more effective residue removal than traditional steel curettes. Statistically, it has been shown that LM Sharp Diamond™ curettes provide a cleaner and more uniform surface than traditional steel curettes.

HygieneVol. 6(2)
University of Padua (IT), University of Milan (IT), Ospedale Civile di Vittorio Veneto (IT)
Openalex Percentile: Top 4%
Periodontal Regeneration and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.